Wiring diagram 1
L and N terminals are connected to live and neutral respectively. The fan is always in standby mode and does not run.
As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round-the-clock ventilation.
As motion sensor is activated (for iFAN Move only) the fan switches to SILENT mode. After no motion is detected the fan
reverts to standby mode. As humidity level increases the fan switches to MAX mode (by default) or to SILENT mode.
After humidity level drops the fan reverts to standby mode.
8
N
N L
L
L
I
L
I
L
T
L
T
L
L
N
N
Standby mode
(fan does not run)
or
24 Hours mode
3
(fan operated at 40/33 m /h)
Turn-on delay
timer starts
(0-2-5 min)
Humidity
change
Motion sensor
is activated
MAX (SILENT)
mode is activated
Fan operation in
Silent mode
Signal to L
I
terminal
(light is off)
Humidity
stabilization
Motion
if off
Signal to L
I
terminal
(light is on)
Humidity extraction
timer starts
(30-45-60 min)
Turn-o
ff
delay
timer starts
(5-15-30 min)
Turn-on delay
timer starts
(0-2-5 min)