Ultima Compact™
Chillers
32 Ultima Compact 30-150kW Technical Manual 9690553 V1.2.0_10_2019
Technical Data
Sound Data
Global Chiller Sound Level
Quiet - X models Models - EC Fans
The Sound Pressure data quoted is only valid in free field conditions. where the unit is installed on
a reflective base. If the equipment is placed adjacent to a reflective wall, values may vary to those
stated, typically increasing by 3dB for each side added.
CAUTION
Frequency (Hz)
Sound
Measurement
63 125 250 500 1000 2000 4000 8000
Overall
[dB(A)]:
UCCL030SR-1AE0 Power
dB
78
71
71
69
72
65
63
60
75
Pressure
@ 10m 47
39
39
38
41
34
32
29
43
UCCL030SR-2AE0 Power
dB
77
82
70
70
73
65
63
60
76
Pressure
@ 10m 45
50
38
38
41
34
31
29
44
UCCL040SR-1AH0 Power
dB
80
71
71
69
72
68
64
65
76
Pressure
@ 10m 48
39
39
37
41
37
33
33
44
UCCL040DR-1ACC Power
dB
80
71
71
69
72
68
64
65
76
Pressure
@ 10m 48
39
39
37
41
37
33
33
44
UCCL040SR-2AH0 Power
dB
81
74
73
71
73
69
64
65
76
Pressure
@ 10m 50
42
42
39
41
37
33
33
45
UCCL040DR-2ACC Power
dB
82
74
74
71
73
69
65
65
77
Pressure
@ 10m 50
42
42
39
41
37
33
33
45
UCCL050SR-2AJ0 Power
dB
81
74
74
72
76
70
67
68
79
Pressure
@ 10m 49
42
42
41
45
39
35
36
47
UCCL050DR-2ADD Power
dB
81
74
74
72
76
70
67
68
79
Pressure
@ 10m 49
42
42
41
45
39
35
36
47
UCCL060SR-2AK0 Power
dB
81
74
74
72
75
68
66
63
78
Pressure
@ 10m 50
42
42
41
44
37
34
32
46
UCCL060DR-2AEE Power
dB
81
74
74
72
75
68
66
63
78
Pressure
@ 10m 50
42
42
41
44
37
34
32
46
UCCL070SR-2AL0 Power
dB
82
74
74
72
75
70
69
64
79
Pressure
@ 10m 50
42
42
41
44
39
37
33
47
UCCL070DR-2AFF Power
dB
82
74
74
72
75
70
69
64
79
Pressure
@ 10m 50
42
42
41
44
39
37
33
47
UCCL075SR-2AM0 Power
dB
82
74
74
72
73
72
71
68
79
Pressure
@ 10m 50
42
42
40
42
40
40
37
47
UCCL075SR-2AP0 Power
dB
82
74
74
72
75
70
69
64
79
Pressure
@ 10m 50
42
42
41
44
39
37
33
47
UCCL075DR-2AGG Power
dB
82
74
74
72
73
72
71
68
79
Pressure
@ 10m 50
42
42
40
42
40
40
37
47
UCCL085SR-2AP0 Power
dB
82
73
74
72
75
70
69
64
79
Pressure
@ 10m 50
41
42
40
44
39
37
33
47
UCCL085DR-2AHH Power
dB
83
73
74
72
75
71
67
68
79
Pressure
@ 10m 51
41
42
40
44
39
36
36
47
UCCL100SR-2AP0 Power
dB
83
78
79
79
78
72
70
65
82
Pressure
@ 10m 51
46
47
47
46
40
38
33
50
UCCL100DR-2AHJ Power
dB
83
78
79
79
79
73
70
70
83
Pressure
@ 10m 52
46
47
47
47
41
38
38
51
UCCL125SR-3AQ0 Power
dB
84
79
81
80
78
74
72
68
83
Pressure
@ 10m 52
47
49
48
46
42
40
36
51
UCCL125DR-3AKK Power
dB
85
79
81
81
80
73
70
67
83
Pressure
@ 10m 53
47
49
49
48
41
38
35
52
UCCL150DR-3AMM Power
dB
85
79
81
81
79
76
75
71
84
Pressure
@ 10m 53
47
49
49
47
44
43
39
52
(1) dB(A) is the overall sound level, measured on the A scale.
(2) All sound data measured at nominal conditions: Water in/out 13/7°C at 35°C ambient.
(3) Based on a unit with a 300mm plenum, for other configurations please see Airedale.
Te
ch
ni
ca
l
R
-T
yp
e
X -
Ty
pe