The SLIMLINE PERFORMER Ceiling Cassette – Ductless Mini-Split
Technical Manual : AIR 8-105.5
Ceiling Cassette
Features
Air Conditioning System Condensing Units
Up Flow Condenser, Model: YCJD18S41S1H through YCJD42S41S1H
Standard Features
•
Quality Condenser Coils
– The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins
for increased efficiency and corrosion protection.
•
Protected Compressor
– The compressor is internally protected against high pressure, temperature, and externally
by a factory installed high pressure switch. This is accomplished by simultaneous operation of high pressure relief
valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line
filter-drier further protects the compressor.
•
Hard Start Kit
- Provides increased starting torque for areas with low voltage.
•
Durable Finish
– The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint
to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish ensure less
fading when exposed to sunlight.
•
Lower Installed Cost
– Installation time and costs are reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means less space is required on the ground or roof.
•
Top Discharge
– The warm air from the top mounted fan is blown up and away from the structure and any
landscaping. This allows compact location on multi-unit applications.
•
Low Operating Sound Level
– The upward air flow carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and rippled fins of the
condenser coil muffle the normal fan motor and compressor operating sounds.
•
Low Maintenance
– Long life permanently lubricated motor-bearings need no annual servicing.
•
Easy Service Access
– Fully exposed refrigerant connections and a single panel covering the electrical controls
makes for easy servicing of the unit.
•
Secured Service Valves
– Secured re-usable service valves are provided on both the liquid and vapor sweat
connections for ease of evacuating and charging.
•
U.L. and C.U.L. Listed
– Approved for outdoor application.
Field Installed Accessories
•
Low Ambient Kit – Fan Cycle Kit
for operation down to 0°F outside temperature.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard
210/240.
Figure 22.1 – Dimensions – DX Cooling Condensing Unit
YCJD18 YCJD24
YCJD30
YCJD36
YCJD42
A = Height
28 28
28
28 30
B = Depth
23½ 23½ 23½ 29
29
C = Width
23½ 23½ 23½ 29
29