Ceiling Cassette
The SLIMLINE PERFORMER Ceiling Cassette – Ductless Mini-Split
15
Technical Manual : AIR 8-105.5
Table 15.1 – Technical Data – DX Cooling Only and Heat Pump Units
Units
CSD/CSH 18
CSD/CSH 24
CSD/CSH 30
CSD/CSH 36
CSD/CSH 42
Nominal Cooling Capacity (1)
BTU/h
19200
23000
31400
38200
42500
Nominal Heating Capacity (2)
BTU/h
16400
21400
27400
32400
37200
Nominal
System
SEER
(3)
13 13 13 13 13
HSPF
7.7 7.7 7.7 7.7 7.7
Construction
Material: Fascia
High Impact Polystyrene
Material: Chassis
Galvanized Steel
Color: Fascia
Pearl Grey
Fire rating
UL94 VO
Evaporator
Type
Finned Tube
Quantity
1 1 1 1 1
Face
Area
Ft²
4.0 4.0 5.2 5.2 5.2
Nominal Airflow High
cfm
590
670
920
1000
1130
Med
cfm
540 590 800 920 1000
Low
cfm
465 540 680 800 920
Discharge
4-way 4-way 4-way 4-way 4-way
Fan
Type
Centrifugal
Quantity
1 1 2 2 2
Diameter
in
14 14 14 14 14
Horsepower
(per
fan) HP
1/8 1/8 1/8 1/8 1/8
Refrigeration
Number of Circuits
1
1
1
1
1
Refrigerant
Type
R-410A R-410A R-410A R-410A R-410A
Weights
Weight
-
Chassis
lb
66 66 97 97 97
Weight
-
Fascia
lb
18 18 21 21 21
Connections (4)
Suction
in
3/4 3/4 3/4 3/4 3/4
Liquid
in
3/8 3/8 3/8 3/8 3/8
Condensate
(ID)
in
3/8 3/8 3/8 3/8 3/8
Filtration
Type
Wire Framed Periframe
Quantity
2 2 3 3 3
Arrestance
80% 80% 80% 80% 80%
Condensate Pump
Maximum
Head
in
30 30 30 30 30
Nominal
Flowrate
gpm
0.1 0.1 0.1 0.1 0.1
Options
Electric
Heating
Capacity
kW
3.0 3.0 5.0 5.0 5.0
HW Heating Capacity (5)
BTU/h
38,746
41,993
56,609
59,600
64,268
HW Coil Connection (OD)
in
7/8
7/8
7/8
7/8
7/8
Max
Branch
Duct
Connections
(qty)
2 2 2 2 2
Branch
Duct
Diameter
in
5 5 6 6 6
Branch Duct Air Volume (6)
cfm
115
130
180
200
220
Fresh Air Connections
(qty)
1-3
1-3
1-3
1-3
1-3
Fresh
Air
Duct
Diameter
in
3 3 3 3 3
Fresh
Air
Volume
(7) cfm
60 65 85 90 95
(1) Nominal cooling capacity based on 80/67°F DB/WB and 95/75ºF DB/WB ambient
(2) Nominal heating capacity based on 70/60°F DB/WB and 47/43°F DB/WB ambient.
(3) Test conditions based on ARI 210/240.
(4) Refrigerant line sizes should always match condensing unit connection sizes.
(5) Nominal heating capacity based on 70/60°F DB/WB and water temperature of 180ºF inlet / 160ºF outlet.
(6) Maximum air volume available through one branch duct 6' long, with Cassette fan(s) at high speed and corresponding fascia
aperture closed.
(7) Maximum fresh air through all knockouts connected to one 10' long duct with fan at high speed.