Trouble shooting the
Carefully following the instructions and guidelines in this manual is the best way to keep your Bulb Eater
®
3
working properly. However, should you encounter problems, this guide will help you resolve issues that
occasionally arise during normal use of the Bulb Eater
®
3. If you are experiencing a problem that is not
addressed here or if your problem persists after following these suggested procedures, do not hesitate to
contact us at 800.909.9709 or
for further assistance.
General Use
Note: If the flashing red & green lights are displayed on the stop & start buttons a fault code will appear
on the LCD display screen
Fault codes Description (Action)
01
Exceeded carbon filter lifetime
(Replace Carbon Canister)
02
Insufficient crusher motor current
(Check crusher motor is plugged in or bad motor)
03
Excessive crusher motor current
(Drum is full or debris on spinner assembly)
04
Crusher motor failed to reach target voltage during startup
(Check crusher motor is plugged
in or bad motor)
05
Fan pressure (carbon filter) didn’t reach target during startup
(Carbon canister not installed)
06
Chute safety cover opened while running
(Safety cover or CFL/U-tube chute not installed)
07
Lid opened while running
(BE3 machine not on drum before starting)
08
Very low carbon filter pressure during startup
(Carbon canister not installed)
09
Excessive carbon filter pressure during startup
(Stage 5 HEPA filter needs to be changed
)
10
Very low HEPA filter pressure during startup
(Plug in entry tube or 3
rd
stage HEPA filter not
installed)
11
Excessive HEPA filter pressure while running
(3
rd
stage HEPA filter needs to be changed)
12
Very low cartridge filter pressure during startup
(2
nd
stage cartridge filter not installed)
13
Excessive cartridge filter pressure while running
(2
nd
stage cartridge filter needs to be
changed)
14
Fan exhaust temperature too high
(Call Air Cycle for guidance)
15
Insufficient fan (carbon filter pressure) while running
(Carbon filter not installed)
16
VBUS voltage below set threshold
(Call Air Cycle for guidance)
17
Heat-sink temperature too high
(Call Air Cycle for guidance)
18
Airlock Failed to rotate or rotation not sensed
(Check airlock motor is plugged in)
19
Parameter values in EEPROM does
n’t match expectation
(Call Air Cycle for guidance)
20
Parameter revision code in EEPROM does not match
(Call Air Cycle for guidance)
21
Corrupt or uninitialized parameter date in EEPROM
(Call Air Cycle for guidance)
22
Transient loss of mains power detected
(Call Air Cycle for guidance)
23
System tilted too far from level
(Change spinner assembly or BE3 machine is not on a flat
surface to operate)
24
Start switch active at power up
(Call Air Cycle for guidance)
25
Crusher motor current indicates high drag condition
(Full drum)
Chute Open
The chute sensor is not sensing the chute safety cover
(Move the safety cover to the left)
Lid Open
Machine has not been activated
(complete training program to download the parameter file)
Still having problems? Contact Air Cycle at 800.909.9709 or 708.344.7860
Operating Tips
1. Do not force lamps down the entry tube. The Bulb E
ater’s vacuum suction should be sufficient to pull the
lamps into the machine.
2. Ensure that you always crush lamps using appropriately sized entry tubes to minimize external breakage.
Entry tubes are available at
www.aircycle.com
for a wide variety of lamp sizes.
3. If you are crushing lamps with significantly blackened ends, feed the lamps blackened end first. These
portions of glass are slightly weaker and more prone to breakage outside the machine.
4. Crushing lamps that have previously been taped together can result in a buildup of adhesive in the Bulb
Eater
®
3
entry tubes and cause breakage. Remove the entry tube from the machine and clean the inside of
the tube with a rag soaked in an appropriate solvent like paint thinner.
Summary of Contents for 333-200-120
Page 2: ......
Page 13: ...800 909 9709 www AirCycle com 10 FIG 4 FIG 5 FIG 7 FIG 10 5 4 FIG 9 FIG 8 FIG 6 6 7 8 10 9...
Page 18: ......
Page 20: ......