Drum Change Procedures
1. Loosen the lid locking bolt & ring on the Bulb Eater
®
3 machine and remove the lid locking ring on the
spare lid.
Figure 1
2. Lift the Bulb Eater
®
3 machine straight up with the spare lid in hand. (requires 2 person for lid change)
Figure 2,3
3. Immediately place the spare lid on the full drum to seal the vapor.
Figure 4
4. Place the Bulb Eater
®
3 Machine on the empty drum and tighten the locking ring.
Figure 5
5. Place the lid locking ring on the lid with the full drum and tighten.
Figure 6
Note:
When this procedure is executed properly, the drum-open time should be less than 10 seconds.