7
Placing the Deflection Sensors in the Brackets
1. Place each deflection sensor in the bracket, oriented so that the
engraved lettering is facing down and
so that the pigtail on the
sensor is facing toward the front of the truck
.
2. Using the washers, nuts, and bolts from the deflection sensor
installation kit, secure the deflection sensor to each bracket
as shown above. Hand-tighten the bolts (do NOT use tools to
tighten).
3. Curl the sensor pigtail cable behind the arm bracket to protect
the cable and connector. Do not allow the cable or connector to
contact the black rubber middle section of the sensor.
4. Connect the shorter extension cable to its deflection sensor on
each side, making sure that the locking tabs on the connector
are engaged completely. Use zip ties to secure the pigtail and
connector to the existing hydraulic lines running behind the
bracket.
Deflection Sensor and Bracket Assembly
4. In the cab of the truck, connect the right-side deflection
sensor extension cable to the port labeled “Right Sensor”
on the ComLink. (Repeat on the left side.) ComLink will be
installed in later step.