background image

it back in. if error repeats, call for service.

 

-

P2

:  Water  tank  is  full.  Empty  the  water 

tank.

 

-

ec

:  Refrigerant  leakage  detection.  With 

this  new  technology,  the  display  area 

will appear 

ec

 when the unit detects 

refrigerant leakage ,call for service

.

 

-

e3

: Unit malfunction. Unplug the unit and 

plug  it  back  in.  if  error  repeats,  call  for 

service.

 

-

eb

: Water tank is removed or not in right 

position.  Replace  it  bucket  in  the  right 

position.

⑩ 

Water tank full indicator light

The indicator lights to indicate that the tank 

is full. 

⑪ 

Auto defrost operation on indicator light

 

The  indicator  lights  to  indicate  that  auto 

defrost operation is on. 

HoW To uSe

• 

Press "Power" 

⑧ 

to  turn  on  and  off  the 

unit. The screen 

 illuminates when 

Kompressor

 is on.

• 

The humidity level can be set with 

   

⑦ 

pads and the digital display 

.

• 

Press the accurate pad in order to initiate 

the desired function of 

Kompressor

 (see  

"Control panel" and "Function" sections).

once  the  function  is  activated,  the 

concerned light indicator lights. 
Press  the  button  again  to  exit  the  selected 

mode. When the tank is full or when it has not 

been placed correctly, the LED "Full" 

 lights 

and 

Kompressor

 stops.

FuNCTIoNS

How  to  use  the  different  functions  of 

Kompressor

• 

Auto Shut off 

The  unit  shuts  off  when  the  bucket  is  full,  or 

when the bucket is removed or not replaced 

in  the  proper  position.  When  the  setting 

humidity  is  reached,  the  unit  will  be  shut  off 

automatically.

• 

Continuous mode 

Continuous  operation  allows  maximum 

dehumidification.  The  unit  dehumidifies 

continuously, without taking into account the 

relative humidity of the ambient air. CAUTioN: 

on this mode, the

     

 pads can not be 

operated. 

• 

Mode HygroSmart

© 

mode

HygroSmart

©

 function allows maximum comfort 

for  the  user.  When  this  function  is  engaged, 

the unit will automatically control the relative 

humidity  on  a  comfortable  range  between 

45%  ~  55%,  depending  on  the  ambient 

temperature. 

CAUTioN: on this monde, the

   

 

 pads can not be operated.

• 

Turbo mode 

Turbo  operation  allows  to  control  the  fan 

speed for more efficiency. Set the fan control 

to  High  for  maximum  moisture  removal. 

CAUTioN:  When  the  humidity  has  been 

reduced and quiet operation is preferred, set 

the fan speed to normal

• 

Timer 

Kompressor

 features an Auto Start and Auto 

Stop  function  within  a  range  of  0  to  24h 

(increments  of  0,5h  between  0  and  10h  ; 

increments of 1h between 10 and 24h). 

Case 1 : the unit is switched off

initialize Auto Start:

 

Press  the  timer  button 

  (the  "timer  on" 

indicator  light  illuminates)  and  use 

   

⑦ 

pads to settle the Auto Start. 
initialize Auto Stop:
Press the timer button 

 two times (the "timer 

off" indicator light illuminates) and use 

   

⑦ 

pads to settle the Auto Stop. 

Case 2 : the unit is switched on

initialize Auto Stop:

 

Press  the  timer  button 

  (the  "timer  off" 

13

Downloaded from www.vandenborre.be

Summary of Contents for Kompressor

Page 1: ...d air 40L jour pompe de relevage int gr e User manual Air dehumidifier 40L day built in drain pump Bedienungsanleitung Luftentfeuchter 40L Tag eingebaute Kondensatpumpe www airnaturel com D o w n l o...

Page 2: ...Pour viter le risque de choc lectrique ne pas exposer le c ble d alimentation des surfaces humides ou mouill es Ne pas tordre ou tirer de mani re excessive sur le c ble lectrique ni poser de choses lo...

Page 3: ...m3 h Dimensions H x L x P 616 x 392 x 282 mm Relevage pompe 5 m Poids net 18 1 kg Consommation 560 W Capacit du r servoir 6 L Zone d efficacit max 200 m Niveau sonore 49 8 dB T d utilisation extr me...

Page 4: ...de la pi ce Pendant la phase de param trage il affiche le taux d humidit d sir ATTENTION l cran peut indiquer plusieurs messages d erreur AS dysfonctionnement de l hygrostat Dans ce cas d brancher pui...

Page 5: ...L appareil s arr te automatiquement lorsque le taux d humidit souhait est atteint Le dispositif de contr le du niveau d eau coupe le fonctionnement du d shumidificateur lorsque le r servoir est plein...

Page 6: ...reil suite une coupure de courant par exemple celui ci red marre dans la derni re configuration programm e d s le retour du courant lectrique ATTENTION Kompressor dispose d un syst me de s curit impos...

Page 7: ...tiquement ferm e gr ce au bouchon pr vu cet effet Connecter l extr mit 4 35 mm du tuyau fourni la sortie de la pompe de drainage enfoncer 15 mm comme indiqu sur le sch ma 4 Installation du tuyau de la...

Page 8: ...Poser sur un sol dur et lisse L appareil est pr vu pour tre utilis entre 5 C et 35 C Laisser au minimum 20 cm d espace autour de l appareil Ne pas brancher une multiprise sur laquelle d autres appare...

Page 9: ...en ferm es La temp rature de la pi ce est inf rieure 5 C Il y a une chaudi re dans la m me pi ce ou un appareil produisant beaucoup de vapeur L appareil fait beaucoup de bruit en fonctionnant Le filtr...

Page 10: ...eat source Turn the unit off when cleaning or emptiying the tank To avoid any electrical shock do not expose the power cord to water or humid surfaces Do not twist or pull excessively on the power cor...

Page 11: ...10A 190 g Airflow max 345 m3 h Dimensions H x W x D 616 x 392 x 282 mm Max rec head 5 m Net weight 18 1 kg Power 560 W Water tank volume 6 L Suitable for rooms up to 200 m Noise level 49 8 dB Ambient...

Page 12: ...ress to turn the dehumidifier on and off LCD screen The screen shows the actual room humidity level then it shows the set humidity level while setting the unit CAUTION the following error codes Can be...

Page 13: ...replaced in the proper position When the setting humidity is reached the unit will be shut off automatically Continuous mode Continuous operation allows maximum dehumidification The unit dehumidifies...

Page 14: ...ssor will cycle off and the fan will continue to run until the frost disappears Removing the collected water Kompressor features three ways to remove collected water 1 Using the water tank When the un...

Page 15: ...e pump drain hose outlet for depth of 15 mm at least See Fig 4 then lead the water hose to the floor drain or a suitable drainage facility Press the pump pad of the unit to activate the pump operation...

Page 16: ...pace on all sides of the unit for good air circulation Do not connect the dehumidifier to a multiple socket outlet which is also being used for other electrical appliances Plug the unit to an electric...

Page 17: ...et low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C There is a kerosene heater or a vapor generating appliance in the room The devic...

Page 18: ...ylon oder anderen brennbaren Stoffen sowie Heizk rper und andere W rmequellen Vor der Wartung oder Pflege des Ger ts bitte immer den Netzstecker herausziehen Um das Risiko eines Stromschlags zu vermei...

Page 19: ...6 x 392 x 282 mm Kondensatpumpe 5 m Nettogewicht 18 1 kg Stromverbrauch 560 W Wasserbeh lterkapazit t 6 L Geeignetf reineRaumgr e 200m Max Lautst rkepegel 49 8 dB Arbeitsbereich Temperatur 5 C bis 35...

Page 20: ...zwischen 0 und 24 einzustellen On Off Power Dr cken Sie um das Ger t ein bzw auszuschalten cran LCD SiezeigtdenFeuchtigkeitsgehaltdesRaumes an W hrend der Konfigurationsphase zeigt sie die gew nschte...

Page 21: ...Funktion aktiviert worden ist leuchtet die betroffene LED auf Dr cken Sie erneut auf die Taste um den ausgew hlten Modus zu verlassen Wenn der Wasserbeh lter voll ist oder wenn er nicht ordnungsgem e...

Page 22: ...worden sind leuchten die LEDs On und Off beide auf ACHTUNG Die Tatsache das Ger t auf eine andere als die oben beschriebene Weise in Betrieb zu nehmen zieht den Verlust der automatischen Einstellungen...

Page 23: ...ermeiden stellen Sie sicher dass der Schlauch nicht verdreht ist und dass die Entw sserung tats chlich durch Schwerkraft stattfinden kann Wenn die kontinuierliche Entw sserung Dauerdrainage nicht verw...

Page 24: ...rPumpezuvermeiden stellen Sie sicher dass der Schlauch nicht verdreht ist und dass nichts den Abfluss des Kondenswassers verhindert Im Falle eines Problems bei der Benutzung der Pumpe blinkt die Anzei...

Page 25: ...bs zuviel L rm Der Filter ist verstopft Das Ger t steht nicht horizontal genug Der Boden ist nicht eben Frost auf dem Kondensator Das ist normal der Luftentfeuchter hat eine Frostschutzfunktion Wasser...

Page 26: ...n inadequate or dangerous use of the products DEEE Disposal of Electric and Electronic Equipment Applicable in the countries of the European Union and other European countries with separate collection...

Page 27: ...U 5 M TRES H REMOVEANYMOISTUREOFYOUR BASEMENTTHANKTOKOMPRESSOR ROOMUPTO200M MAX RECOMMENDED HEAD 5 METERS H ENTFERNENSIEFEUCHTIGKEITAUS DEMKELLERDANKKOMPRESSOR BISZU200M MAXIMALE UNVERBINDLICHE H HE 5...

Page 28: ...Le bien air chez soi 18 22 rue d Arras Bat 13 92000 NANTERRE FRANCE info airnaturel com 339 72 232 232 D o w n l o a d e d f r o m w w w v a n d e n b o r r e b e...

Reviews: