background image

SA-102 

Smart In Wall Dual Switch 

User Manual 

Summary of Contents for SA-102

Page 1: ...SA 102 Smart In Wall Dual Switch User Manual ...

Page 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...

Page 3: ...s device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any oth...

Page 4: ...ser Manual iii Table of Contents 1 Overview 1 1 1 Adding to Z WaveTM Network 1 1 2 Auto Inclusion 2 1 3 LED Indication 3 1 4 Choosing a Suitable Location 3 1 5 Installation 4 1 6 Programming 4 1 7 Troubleshooting 19 1 8 Specification 20 ...

Page 5: ...ight like incandescent fluorescent and LED light This in wall switch module is able to detect Instant power wattage and overload current 7 5A with resistive load of connected light or appliances When detecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly However disconnect and re connect the Module will reset its overload conditio...

Page 6: ...n Annotation No node ID The Z Wave Controller does not allocate a node ID to the Switch LED 2 second on 2 second off Inclusion 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer One press one flash LED Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode Exclusion Put your Z Wave controller into exclusion...

Page 7: ...hen first time connect to main power 1 3 LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LED Indication Normal Whatever we switch On and off of the SA 102 by S1 S2 or On Off button or RF command the LED will lights up 1 second and then off No node ID Under normal operation when the Switch has not been allocated a node ID the LED flashes on a...

Page 8: ...ill also turn ON 4 To manually turn OFF the Switch simply press and release the On Off button The LED will light ON for 1 second and the load plugged into the Switch will turn OFF 1 6 Programming 1 6 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY SWITCH commands that are part of the Z Wave system 1 BASIC_GET BINARY_SWITCH_GET Since the switch have two...

Page 9: ...Configuration parameter 3 2 switch ON and OFF of relay 2 Configuration parameter 3 3 default switch ON and OFF both relay 1 and relay 2 Command Class Basic Basic Set Value 1 99 255 0xFF the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF the load attached to t...

Page 10: ...report When the power consumption of load vary over 5 it will send Meter report to the nodes of Group Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 1 6 2 3 Overload alarm report command When SA 102 detect the overload it will send Alarm Report to the correspond Group The content of Alarm Report Alarm report command ...

Page 11: ...eter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x00 Size 4 Meter Value KWh Example Scale 0x00 KWh Precision 2 Size 4 Bytes KW h Meter Value 1 0x00 KWh Meter Value 2 0x01 KWh Meter Value 3 0x38 KWh Meter Value 4 0xA3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 1 6 3 3 Clearing accumulated power consumption Whenever re st...

Page 12: ...r Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 1 6 3 6 Load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale ...

Page 13: ...d Point range from 1 3 Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x02 Switch_Binary_Get 0x02 Below is the example show SA 102 report to last command COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Since the endpoint is 3 so SA 102 will reply ON 0xFF when either Relay 1 or Relay2 is ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Bit Address Desti...

Page 14: ...e show how to get the meter report type COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x01 this is the endpoint of command inquirer here we assume endpoint is 1 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x03 Meter...

Page 15: ...ER_GET Using meter get command to get the KWH W V I PF from endpoint of SA 102 1 6 4 5 1 Get KWH from endpoint Meter_GET example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit Address 0 Destina...

Page 16: ... 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit Address 0 Destination End Point range 1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x01 Meter_Get 0x01 Parameter 1 0x10 Scale W 0x02 SA 102 Instant Power Consumption W Report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report End...

Page 17: ...le V 0x04 SA 102 AC load Voltage report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0 Destination End Point command inquirer s Endpoint value Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x02 Meter_Report 0x02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Paramet...

Page 18: ... Command_Class_Meter_V3 0x32 Command 0x02 Meter_Report 0x02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x4A Precision 2 Scale Bit1Bit0 0x01 Size 2 Parameter 3 0x00 Current 0x002B 0 43A Parameter 4 0x2B 1 6 4 5 5 Get power factor PF from endpoint Meter_GET example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command ...

Page 19: ... 1 Watt Meter Report Period 2 0x01 0x7FFF 5s 720 720 5s 3600s 1 hour 2 KWH Meter Report Period 2 0x01 0x7FFF 10min 6 6 10min 1 hour 3 Selected Relay 1 1 3 3 1 Relay1 2 Relay2 3 Relay1 Relay2 4 Edge or Pulse mode or Edge Toggl e mode 1 1 3 1 1 Edge mode 2 Pulse mode 3 Edge Toggle mode 5 Threshold of current for Load Caution 2 10 750 0 01A 750 750 0 01A 7 5A 6 Threshold of KWH for Load Caution 2 1 1...

Page 20: ...select value to react the Basic Command Class Binary Switch Command Class or Meter Command Class V3 1 6 5 3 1 Selected Relay1 Only relay1 can be controlled and report 1 6 5 3 2 Selected Relay 2 Only relay2 can be controlled and report 1 6 5 3 3 Selected Relay1 and Relay2 Default select is 3 Both relay1 and relay2 can be controlled and report Set command Relay state Basic_Set or Binary_Switch_Set O...

Page 21: ...en the current of load over the preset threshold value if the setting value is 750 when the load current of Relay1 or Relay2 over this value SA 102 will send current meter report to the node of correspond Group the Range of the setting value is from 10 to 750 and the default value is 750 1 6 5 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold valu...

Page 22: ...t can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button or S2 S2 should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because...

Page 23: ... Check power connections Don t open up the Switch and send it for repair The Switch LED illuminating but cannot control the ON OFF Switch of the load attached Check if the load connect into the Switch has its own ON OFF switch Set the ON OFF switch of the load attached to ON The Switch LED illuminating but the Detector cannot control the Switch Not carry out association Same frequency interference...

Page 24: ...inimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range SA 102 1 868 40MHz 869 85MHz EU SA 102 2 908 40MHz 916 00MHz USA Canada SA 102 3 922 5MHz 923 9MHz 926 3MHz Taiwan JP Specifications are subject to change and improvement without notice OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 ...