4. OPERATION
4.1
FRONT PANEL CONTROLS
1.
WIRE SPEED CONTROL
Use this control to adjust wire feed speed. When
wire speed is increased, welding amperage
increases. When wire feed speed decreases,
welding amperage decreases.
2.
VOLTAGE SWITCH
Use this control to turn the wire feed unit on and to
adjust welding voltage. Thicker material will
require higher voltage settings.
Do not switch under load
3.
DATA PLATE
M 132
M 172
4.2
BACK PANEL CONTROLS
1.
GAS CONNECTIONS
2.
INPUT POWER CORD
5. MAINTENANCE AND TROUBLESHOOTING
DISCONNECT THE POWER
SOURCE FROM POWER SUPPLY BEFORE
PERFORMING ANY MAINTENANCE WORK.
Periodically, remove the side panels and blow out
the machine with dry compressed air to remove
dirt and dust.
Increase the frequency of cleaning when operat-
ing in dirty or dusty conditions.
5.1
TORCH MAINTENANCE
As required, clean the interior of the gas nozzle to
prevent buildup of spatter.
To change the contact tip:
1. Slide off the gas nozzle.
2. Unscrew the contact tip.
3. Fit the new contact tip.
4. Replace the gas nozzle.
To change the gas diffuser:
1.
Slide off the gas nozzle.
2.
Unscrew the contact tip.
3.
Unscrew the gas diffuser and replace.
4.
Fit the contact tip.
5.
Fit the gas nozzle.
The same switch is to be used to turn the power ON and OFF.
12
Summary of Contents for M 132
Page 9: ...INSTALLING WELDING GUN TURN OFF WELDER BEFORE MAKING CONNECTIONS 9 1 4 2 3 ...
Page 34: ...1 4 2 3 34 INSTALACIÓN APAGUE LA SOLDADORA ANTES DE REALIZAR CONEXIONES ...
Page 39: ... ...
Page 42: ...42 ELECTRICAL DIAGRAM SCHÉMA ÉLECTRIQUE DIAGRAMA ELÉCTRICO M 132 ...
Page 43: ...43 ELECTRICAL DIAGRAM SCHÉMA ÉLECTRIQUE DIAGRAMA ELÉCTRICO M 172 ...
Page 44: ...44 SPARE PARTS LIST PIECES DETACHEES LISTA PIEZAS DE RICAMBIO M 132 ...
Page 46: ...46 SPARE PARTS LIST PIECES DETACHEES LISTA PIEZAS DE RICAMBIO M 172 ...
Page 49: ...49 ...