Troubleshooting Guide
TROUBLESHOOTING GUIDE
WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS.
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM.
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.
REPLACEMENT PARTS LIST
UVC Germicidal Lamp
Part Number: 602607301
For replacement parts, contact Air+Health at:
PHONE
1.866.765.1587
FAX
1.866.253.1029
WEB
airhealth.com
Scan QR: install guide
airhealth.com/diy-installation/
UVC LAMP NOT LIGHTING UP:
1.
Pull back metal washer on left side of mounting base. If lamp
lights up, the base needs tightening to ensure that the safety
switch is fully engaged. (Reference Figure 20 on page 19.)
2.
If lamp does not light up, rotate ballast slightly clockwise or
counter-clockwise.
3.
If lamp does not light up after rotating ballast, replace lamp.
4.
If unit still does not light up after replacing lamp, replace ballast.
BROKEN LAMPS
(see safety considerations)
UV lamps contain a small amount of mercury, like a typical
fluorescent lamp. DO NOT touch any of the mercury with your
bare hands.
1.
While wearing disposable, non-absorbent protective gloves,
pick up the large pieces of glass with your hands.
2.
Then, vacuum the entire area with a standard household vacuum
cleaner ensuring the removal of all lamp material.
3.
Dispose of the pieces of glass, the vacuum cleaner bag, and the
disposable gloves in a sealed garbage bag.
4.
Check with your local waste management authority for local
disposal or recycling requirements. According to the EPA’s
Universal Waste Rule, these types of lamps may be disposed of
into household waste.
5.
Wash hands and remove and wash clothes for added
safety measures.