UVC Lamp Replacement 

(Continued)

REPLACEMENT PROCEDURE

5. Wipe off UVC lamp with alcohol wipe.  

Wipe off the glass with the supplied alcohol wipe. 

6. Insert the UVC lamp into the mounting base hole. 

Position the ballast assembly power cord 90° to the view port 
hole on the mounting base. Slide the lamp through the hole in 
the mounting base. (See Figure 26)

7. Secure the ballast to the mounting base.

Press the ballast against the mounting base and rotate the 
ballast assembly clockwise until it stops. (See Figure 27 & 28)

8. Plug Haven Plus in.

After assembly is firmly in place, plug the power supply cord 
into a standard electrical wall outlet. Check lamp operation by 
looking through the view port hole. A blue glow should be 
seen in the duct.

NOTE:

 If blue light leaks through any portion of plenum and/or around 

mounting plate, unplug power supply cord immediately and seal affected 
areas and/or rotate ballast and repeat step #8 above.

9. Dispose of the old UVC lamp according to 

local regulations.

UVC lamps contain a small amount of mercury, like a typical 
fluorescent lamp. Check with your local waste management 
authority for local disposal or recycling requirements. 
According to the EPA’s Universal Waste Rule, these types 
of lamps may be disposed of into household waste.

WARNING:

 Never touch broken lamp or internal contents of lamp. 

The lamp contains mercury.

NOTE:

 In case of accidental exposure to internal contents of lamp, 

wash hands and any other affected skin area with mild detergent. 
Remove affected clothing immediately. If skin surface is pierced, 
seek medical attention immediately.

VIEW PORT

CORD

FIGURE 26

TURN CLOCKWISE

LOCKED POSITION

SAFETY SWITCH

SAFETY SWITCH

ENGAGED

SAFETY SWITCH

 NOT

 ENGAGED

TURN CLOCKWISE

LOCKED POSITION

SAFETY SWITCH

SAFETY SWITCH

ENGAGED

SAFETY SWITCH

 NOT

 ENGAGED

FIGURE 27

FIGURE 28

WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING 
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS. 
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM. 
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.

Summary of Contents for Haven Plus

Page 1: ...PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY before proceeding with the installation Whole Home Protection Scan QR install guide airhealth com diy installation PLUS INSTALLATION USER MANUAL...

Page 2: ...nation of photo catalytic chemical reaction and carbon absorption as air passes through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously...

Page 3: ...o internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If y...

Page 4: ...g this product 7 Screws x4 4 sheet metal screws 8 Alcohol Wipe For cleaning the lamp Tools Required Marker Power Drill Gloves Screwdriver Flat Head Metal Shears Duct Tape MEET YOUR NEW HAVEN PLUS WARN...

Page 5: ...parate Air Handler in the attic or crawl space A C CONDENSER A C CONDENSER A C CONDENSER A C CONDENSER How to identify your HVAC system type 1 Use Figure A to identify which type of system you have 2...

Page 6: ...he unit in the supply plenum as close as possible to the A coil Reference Figure B to pick the best install location for your system s air flow direction NOTE SEAL the joints and seams of the plenum n...

Page 7: ...to duct Hold or temporarily tape the supplied mounting plate in the location chosen for installation and use the plate as a template to mark the duct along the outermost slots in the plate see Figure...

Page 8: ...bend point See Figure 5 Bend both tabs at the second bend point up and down to pinch and grip the duct material See Figure 6 FIGURE 5 FIGURE 7 FIGURE 6 INSIDE DUCT Duct Board Mounting Duct Board Mount...

Page 9: ...e unit can be rotated so that the view port is always easy to access Directions for airflow Up Flow The unit should be mounted as shipped Horizontal Flow The entire unit including the ballast should b...

Page 10: ...C lamp into the ballast assembly lamp socket See Figure 15 7 Wipe off UVC lamp with alcohol wipe Wipe off the lamp glass with the supplied alcohol wipe 8 Insert the UVC lamp and ballast into the mount...

Page 11: ...the plated washer on the switch is raised approximately 3 16 and the switch is fully engaged See Figure 20 11 Seal all joints and seams With standard duct tape seal any joints and seams near the mount...

Page 12: ...substrate with solutions Do not attempt to clean the catalytic aluminum substrate core with cleaning solutions The catalyst is radiated with short wave ultraviolet light during period of non air flow...

Page 13: ...Remove the old lamp from the lamp socket See Figure 24 4 Install replacement UVC lamp Install replacement lamp into lamp socket Do not handle the lamp with bare hands Oils on the hands may reduce lam...

Page 14: ...and or rotate ballast and repeat step 8 above 9 Dispose of the old UVC lamp according to local regulations UVC lamps contain a small amount of mercury like a typical fluorescent lamp Check with your...

Page 15: ...If lamp does not light up rotate ballast slightly clockwise or counter clockwise 3 If lamp does not light up after rotating ballast replace lamp 4 If unit still does not light up after replacing lamp...

Page 16: ...replace it and return it to the purchaser This warranty is limited to the original retail purchaser and is not transferable The warranty does not cover damage due to accidents abuse tampering or misu...

Page 17: ...765 1587 READ ALL INSTRUCTIONS BEFORE USING PLEASE SAVE FOR REFERENCE Air Health Support Visit airhealth com support for online help support videos general tips and useful information about Haven Plu...

Reviews: