24
25
UVC Lamp Replacement
(Continued)
REPLACEMENT PROCEDURE
5. Wipe off UVC lamp with alcohol wipe.
Wipe off the glass with the supplied alcohol wipe.
6. Insert the UVC lamp into the mounting base hole.
Position the ballast assembly power cord 90° to the view port
hole on the mounting base. Slide the lamp through the hole in
the mounting base. (See Figure 26)
7. Secure the ballast to the mounting base.
Press the ballast against the mounting base and rotate the
ballast assembly clockwise until it stops. (See Figure 27 & 28)
8. Plug Haven Plus in.
After assembly is firmly in place, plug the power supply cord
into a standard electrical wall outlet. Check lamp operation by
looking through the view port hole. A blue glow should be
seen in the duct.
NOTE:
If blue light leaks through any portion of plenum and/or around
mounting plate, unplug power supply cord immediately and seal affected
areas and/or rotate ballast and repeat step #8 above.
9. Dispose of the old UVC lamp according to
local regulations.
UVC lamps contain a small amount of mercury, like a typical
fluorescent lamp. Check with your local waste management
authority for local disposal or recycling requirements.
According to the EPA’s Universal Waste Rule, these types
of lamps may be disposed of into household waste.
WARNING:
Never touch broken lamp or internal contents of lamp.
The lamp contains mercury.
NOTE:
In case of accidental exposure to internal contents of lamp,
wash hands and any other affected skin area with mild detergent.
Remove affected clothing immediately. If skin surface is pierced,
seek medical attention immediately.
VIEW PORT
CORD
FIGURE 26
TURN CLOCKWISE
LOCKED POSITION
SAFETY SWITCH
SAFETY SWITCH
ENGAGED
SAFETY SWITCH
NOT
ENGAGED
TURN CLOCKWISE
LOCKED POSITION
SAFETY SWITCH
SAFETY SWITCH
ENGAGED
SAFETY SWITCH
NOT
ENGAGED
FIGURE 27
FIGURE 28
WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS.
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM.
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.