20
21
WARNING:
UNPLUG
Unplug unit from outlet before commencing inspection and cleaning.
SAFETY PROCEDURE
Please wear disposable, non-absorbent protective gloves prior to inspection
procedure in case of accidental breakage of glass.
1. Inspect and clean UVC lamp every 6 months.
We recommend inspecting and cleaning the UVC lamp at least every 6
months depending upon your home environment, condition of
conventional filters and duration of use and their replacement cycle.
2. Inspect and clean UVC lamp annually.
To maintain the lamps maximum output intensity, replace your UVC
lamp annually, depending upon your home environment using the
replacement procedure below. The lamp should operate continuously
for maximum lamp life and light effectiveness.
3. Do not clean the filters (catalytic aluminum substrate)
with solutions.
Do not attempt to clean the catalytic aluminum substrate core with
cleaning solutions. The catalyst is radiated with short wave ultraviolet
light during period of non-air flow and is self-cleaning. If there is build
up blocking the catalytic cells, sit the unit on end (on a flat surface)
with electrical enclosure facing up. Use low-pressure, compressed air
to blow the surface of the catalytic cells free of blockage.
Maintenance
MAINTENANCE
REPLACEMENT PARTS LIST
UVC Germicidal Lamp
Part Number: 602607301
For replacement parts, contact Air+Health at:
PHONE
1.866.765.1587
FAX
1.866.253.1029
WEB
airhealth.com
Scan QR: install guide
airhealth.com/diy-installation/
WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS.
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM.
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.