WARNING: 

UNPLUG

Unplug unit from outlet before commencing inspection and cleaning.

SAFETY PROCEDURE

Please wear disposable, non-absorbent protective gloves prior to inspection 
procedure in case of accidental breakage of glass.

1. Inspect and clean UVC lamp every 6 months.

We recommend inspecting and cleaning the UVC lamp at least every 6 
months depending upon your home environment, condition of 
conventional filters and duration of use and their replacement cycle.

2. Inspect and clean UVC lamp annually.

To maintain the lamps maximum output intensity, replace your UVC 
lamp annually, depending upon your home environment using the 
replacement procedure below. The lamp should operate continuously 
for maximum lamp life and light effectiveness. 

3. Do not clean the filters (catalytic aluminum substrate) 

    with solutions.

Do not attempt to clean the catalytic aluminum substrate core with 
cleaning solutions. The catalyst is radiated with short wave ultraviolet 
light during period of non-air flow and is self-cleaning. If there is build 
up blocking the catalytic cells, sit the unit on end (on a flat surface) 
with electrical enclosure facing up. Use low-pressure, compressed air 
to blow the surface of the catalytic cells free of blockage.

Maintenance

MAINTENANCE

REPLACEMENT PARTS LIST

UVC Germicidal Lamp

Part Number: 602607301

For replacement parts, contact Air+Health at:

PHONE

   1.866.765.1587

FAX

  

 1.866.253.1029

E-MAIL 

 [email protected]

WEB

 

 airhealth.com

Scan QR: install guide

airhealth.com/diy-installation/

WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING 
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS. 
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM. 
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.

Summary of Contents for Haven Plus

Page 1: ...PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY before proceeding with the installation Whole Home Protection Scan QR install guide airhealth com diy installation PLUS INSTALLATION USER MANUAL...

Page 2: ...nation of photo catalytic chemical reaction and carbon absorption as air passes through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously...

Page 3: ...o internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If y...

Page 4: ...g this product 7 Screws x4 4 sheet metal screws 8 Alcohol Wipe For cleaning the lamp Tools Required Marker Power Drill Gloves Screwdriver Flat Head Metal Shears Duct Tape MEET YOUR NEW HAVEN PLUS WARN...

Page 5: ...parate Air Handler in the attic or crawl space A C CONDENSER A C CONDENSER A C CONDENSER A C CONDENSER How to identify your HVAC system type 1 Use Figure A to identify which type of system you have 2...

Page 6: ...he unit in the supply plenum as close as possible to the A coil Reference Figure B to pick the best install location for your system s air flow direction NOTE SEAL the joints and seams of the plenum n...

Page 7: ...to duct Hold or temporarily tape the supplied mounting plate in the location chosen for installation and use the plate as a template to mark the duct along the outermost slots in the plate see Figure...

Page 8: ...bend point See Figure 5 Bend both tabs at the second bend point up and down to pinch and grip the duct material See Figure 6 FIGURE 5 FIGURE 7 FIGURE 6 INSIDE DUCT Duct Board Mounting Duct Board Mount...

Page 9: ...e unit can be rotated so that the view port is always easy to access Directions for airflow Up Flow The unit should be mounted as shipped Horizontal Flow The entire unit including the ballast should b...

Page 10: ...C lamp into the ballast assembly lamp socket See Figure 15 7 Wipe off UVC lamp with alcohol wipe Wipe off the lamp glass with the supplied alcohol wipe 8 Insert the UVC lamp and ballast into the mount...

Page 11: ...the plated washer on the switch is raised approximately 3 16 and the switch is fully engaged See Figure 20 11 Seal all joints and seams With standard duct tape seal any joints and seams near the mount...

Page 12: ...substrate with solutions Do not attempt to clean the catalytic aluminum substrate core with cleaning solutions The catalyst is radiated with short wave ultraviolet light during period of non air flow...

Page 13: ...Remove the old lamp from the lamp socket See Figure 24 4 Install replacement UVC lamp Install replacement lamp into lamp socket Do not handle the lamp with bare hands Oils on the hands may reduce lam...

Page 14: ...and or rotate ballast and repeat step 8 above 9 Dispose of the old UVC lamp according to local regulations UVC lamps contain a small amount of mercury like a typical fluorescent lamp Check with your...

Page 15: ...If lamp does not light up rotate ballast slightly clockwise or counter clockwise 3 If lamp does not light up after rotating ballast replace lamp 4 If unit still does not light up after replacing lamp...

Page 16: ...replace it and return it to the purchaser This warranty is limited to the original retail purchaser and is not transferable The warranty does not cover damage due to accidents abuse tampering or misu...

Page 17: ...765 1587 READ ALL INSTRUCTIONS BEFORE USING PLEASE SAVE FOR REFERENCE Air Health Support Visit airhealth com support for online help support videos general tips and useful information about Haven Plu...

Reviews: