SAFETY CONSIDERATIONS

WARNING

 Never expose eyes or skin to UVC light from any source.

•  Looking directly at the UVC light may cause permanent eye damage 

or blindness.

•  Never operate the Air+Health™ Haven Plus out of the plenum.
•  Designed for a closed duct system. Do not mount near a supply or a 

return air opening.

•  All duct openings in direct line of site of the UV light must be sealed 

with aluminum tape or equivalent sealing methods.

•  Wear supplied safety glasses during installation. 

WARNING

 UVC light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)

•  The unit must be mounted at least 30” from the above stated type 

of materials.

•  If it is necessary to mount the unit in direct line of sight of these 

types of materials, they must be shielded with aluminum foil, 
aluminum foil tape, or sheet metal.

WARNING

DO NOT mount this unit outdoors.

•  This product is designed for indoor installation only (i.e. Attics, crawl 

spaces, basements, etc.).

WARNING

Never touch broken lamp or internal contents of lamp. The lamp 
contains mercury.

•  After opening the carton, unpack and inspect the unit and lamp for 

damage. Do not install this unit if any damage is noticeable. If lamp 
is damaged, cracked or broken, do not touch lamp or other contents 
in carton. Close carton and return to seller immediately.

•  In case of accidental exposure to internal contents of lamp, wash 

hands and any other affected skin area with mild detergent. 
Remove affected clothing immediately. If skin surface is pierced, 
seek medical attention immediately.

NOTE:

 If you touch the glass of the lamp, you should wipe the glass clean 

with isopropyl alcohol and a lint free wipe. If the lamp is not cleaned, the film 
of hand oils causes a reduction in the light intensity.

WARNING

Before installing or servicing a humidifier, air filter, heat system, this unit,  
etc., always turn all power OFF and have unit unplugged. Electrical shock can 
cause personal injury or death. Never expose eyes or skin to direct UVC light 
from any source.

WARNING

To prevent water damage or electric shock, do not mount unit under 
a humidifier.

WARNING

This product is designed for indoor installation only (i.e. attics, crawl spaces, 
basements, etc.). For use on gas fired, oil fired, electric and split system heat 
pump forced air systems

*

. This product is NOT designed to be mounted 

outside on gas fired or heat pump packaged units

**

.

*

Split system heat pumps are systems where the air handler and the air 

conditioning compressor are separate units.

**

Packaged units are systems where the air handler and the air conditioning 

compressor are built together and are installed outside of the building.

Safety Considerations

WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING 
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS. 
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM. 
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.

Summary of Contents for Haven Plus

Page 1: ...PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY before proceeding with the installation Whole Home Protection Scan QR install guide airhealth com diy installation PLUS INSTALLATION USER MANUAL...

Page 2: ...nation of photo catalytic chemical reaction and carbon absorption as air passes through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously...

Page 3: ...o internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If y...

Page 4: ...g this product 7 Screws x4 4 sheet metal screws 8 Alcohol Wipe For cleaning the lamp Tools Required Marker Power Drill Gloves Screwdriver Flat Head Metal Shears Duct Tape MEET YOUR NEW HAVEN PLUS WARN...

Page 5: ...parate Air Handler in the attic or crawl space A C CONDENSER A C CONDENSER A C CONDENSER A C CONDENSER How to identify your HVAC system type 1 Use Figure A to identify which type of system you have 2...

Page 6: ...he unit in the supply plenum as close as possible to the A coil Reference Figure B to pick the best install location for your system s air flow direction NOTE SEAL the joints and seams of the plenum n...

Page 7: ...to duct Hold or temporarily tape the supplied mounting plate in the location chosen for installation and use the plate as a template to mark the duct along the outermost slots in the plate see Figure...

Page 8: ...bend point See Figure 5 Bend both tabs at the second bend point up and down to pinch and grip the duct material See Figure 6 FIGURE 5 FIGURE 7 FIGURE 6 INSIDE DUCT Duct Board Mounting Duct Board Mount...

Page 9: ...e unit can be rotated so that the view port is always easy to access Directions for airflow Up Flow The unit should be mounted as shipped Horizontal Flow The entire unit including the ballast should b...

Page 10: ...C lamp into the ballast assembly lamp socket See Figure 15 7 Wipe off UVC lamp with alcohol wipe Wipe off the lamp glass with the supplied alcohol wipe 8 Insert the UVC lamp and ballast into the mount...

Page 11: ...the plated washer on the switch is raised approximately 3 16 and the switch is fully engaged See Figure 20 11 Seal all joints and seams With standard duct tape seal any joints and seams near the mount...

Page 12: ...substrate with solutions Do not attempt to clean the catalytic aluminum substrate core with cleaning solutions The catalyst is radiated with short wave ultraviolet light during period of non air flow...

Page 13: ...Remove the old lamp from the lamp socket See Figure 24 4 Install replacement UVC lamp Install replacement lamp into lamp socket Do not handle the lamp with bare hands Oils on the hands may reduce lam...

Page 14: ...and or rotate ballast and repeat step 8 above 9 Dispose of the old UVC lamp according to local regulations UVC lamps contain a small amount of mercury like a typical fluorescent lamp Check with your...

Page 15: ...If lamp does not light up rotate ballast slightly clockwise or counter clockwise 3 If lamp does not light up after rotating ballast replace lamp 4 If unit still does not light up after replacing lamp...

Page 16: ...replace it and return it to the purchaser This warranty is limited to the original retail purchaser and is not transferable The warranty does not cover damage due to accidents abuse tampering or misu...

Page 17: ...765 1587 READ ALL INSTRUCTIONS BEFORE USING PLEASE SAVE FOR REFERENCE Air Health Support Visit airhealth com support for online help support videos general tips and useful information about Haven Plu...

Reviews: