COMPLIANCE INFORMATION
Bio Cart HEPA-UVC 13LT complies with all relevant health and safety guidelines for
portable, negative air, dust containment carts used in healthcare facilities such as
ICRA 1 through 4, and others listed below.
Because the occupants of healthcare facilities are often more susceptible
contaminates introduced into the air by routine maintenance work to and above the
ceilings, the Center for Disease Control (CDC) has created strict guidelines for how this
work must be performed while minimizing the risks to sensitive individuals in its
guidelines for Infection Control in Healthcare Facilities (ICRA).
Activities such as testing fire and smoke sensors, adding or rerouting wires and fiber
optic lines for IT equipment, cleaning air system components, changing electrical
wiring, all must include consideration for controlling the amount of dust and
infectious particles that might be disturbed and introduced into the air.
The Bio Cart HEPA-UVC 13LT is a portable containment cart that extend to any ceiling
13 ft 2 in high, with a ladder that remains inside to reach the work area. The Bio Cart
HEPA-UVC 13LT provides negative pressure and air exchange rates to comply with CDC
guidelines to contain dust and infectious particles. Bio Cart HEPA-UVC 13LT adds
UVGI irradiation in the HEPA Filter compartment to neutralize infectious particles
captured by the 99.97% HEPA filter. The clean air is then exhausted out the bottom as
a diffused flow so it cannot disturb documents on desks. The Bio Cart HEPA-UVC 13LT
complies with the CDC's ICRA 1-4 Guidelines, and also meets fire control guides for
using flame retardant materials and able to quickly be relocated from fire evacuation
routes.
Built to Compliances, Standards, and Recommendations
ASHRAE 52.2:2007
ICRA Class 1-4 Compliant
OSHA 1910.1000 Air Contaminants: Nuisance Dust
OSHA IMIS
• 9135, 9130
OSHA/ACGIH Respirable Dust Compliant
CDC/HICPAC Guidelines for Environmental Infection Control in Health-Care Facilities
• 3.b, 3.b, 3.d.iii, 3.d.iv
• Part IV Appendix B. Air,
VI.C.1. Environmental controls
• VI.C.1.a, V.I.C.2, V.I.E.
Air-Care | 800.322.9919 | [email protected]
31
June 2018 - Part # FG0179
Made in the USA
Summary of Contents for Bio Cart HEPA-UVC 13 LT
Page 1: ...Air Care 800 322 9919 cs air care com 1 June 2018 Part FG0179 Made in the USA ...
Page 6: ...CONTROL PANEL Air Care 800 322 9919 cs air care com 6 June 2018 Part FG0179 Made in the USA ...
Page 7: ...TABLET Air Care 800 322 9919 cs air care com 7 June 2018 Part FG0179 Made in the USA ...
Page 32: ...Air Care 800 322 9919 cs air care com 32 June 2018 Part FG0179 Made in the USA ...