SAFETY INFORMATION
Air-Care Bio Carts are designed to minimize hazards from dust and debris released
from the Ceiling area when work is performed there. The Bio Cart HEPA-UVC 13LT
has electrical power and components around which common sense and normal
safety procedures must be followed to minimize exposure to any possible dangers.
The Electrical Plug is fitted with a GFI (Ground Fault Interrupter) to shut down power
if there is a defective device with improper ground plugged in to the Bio Cart HEPA-
UVC 13LT power. Do NOT replace this plug with a normal, non-GFI plug. Do NOT
remove the ground pin on the GFI plug. Always plug the power cord into a grounded
electrical outlet.
When the Bio Cart HEPA-UVC 13LT is located in the work area, set the Wheel Brakes
and swivel locks before stepping inside the Cart to prevent movement that May
cause the technician to lose their balance.
The Ladder MUST be fully seated into the bottom Brackets, and the upper support is
secured to the ladder with the Clamps provided on the support prior to the
technician stepping on to the Ladder. When moving the Ladder, it must be secured
with the strap and snap lock attached to one side. This will hold the 3 sections of
ladder in a stable configuration while being moved. To move the Bio Cart HEPA-UVC
13LT through doorways, the base of the ladder must be moved toward the door, but
do NOT use the ladder in this position.
The Bio Cart HEPA-UVC 13LT is equipped with 2 UVC/UVGI lamps
above the HEPA. To prevent eye damage the Bio Cart has a clear
window filter that does not allow UVC light to escape, just the
safe, “blue” component of the lamps, which is visible. When
changing the HEPA filter, an interlock turns off the UVC/UVGI
lamps and the Air Scrubber fan motor. DO NOT BY PASS this
interlock and if the window is not in place, turn off the UVC/UVGI
lamps with the switch on each box above that window.
Air-Care | 800.322.9919 | [email protected]
25
June 2018 - Part # FG0179
Made in the USA
Summary of Contents for Bio Cart HEPA-UVC 13 LT
Page 1: ...Air Care 800 322 9919 cs air care com 1 June 2018 Part FG0179 Made in the USA ...
Page 6: ...CONTROL PANEL Air Care 800 322 9919 cs air care com 6 June 2018 Part FG0179 Made in the USA ...
Page 7: ...TABLET Air Care 800 322 9919 cs air care com 7 June 2018 Part FG0179 Made in the USA ...
Page 32: ...Air Care 800 322 9919 cs air care com 32 June 2018 Part FG0179 Made in the USA ...