background image

12

When receiving multiple calls

The following operations can be performed.

 Answering with handset

Press the selector button of 

the calling station.

NIM system

If the handset is picked up without 

selecting the calling station, the 
fi rst-come call is received.

Pick up the handset and talk 

with the caller.

Station 6

Station 7

Station 8

Station 9

Corridor light and indicators on 

the equipment other than the 
master station turns off at the 
start of talking.

To end the communication, 

hang up the handset.

The call-in/talk indicator for the 
caller turns off.

To answer the next call, press 

OFF

 with the handset still off 

hook.

The ringtone sounds and the call-

in/talk indicators for other calls 
blink red. To answer another call, 
repeat step 

1

 - 

3

.

 Answering in Push-to-Talk 

mode

Press the station selector 

button of the calling station.

NIM system

If this step is skipped, the fi rst-

come call is automatically selected.

Press

  TALK  

and begin talking 

with the caller.

To speak

Press and hold 

TALK

 while 

speaking.

To listen to the caller

Release 

TALK

 while listening.

Corridor light and indicators on the 

equipment other than the master 
station turns off at the start of talking.

To end communication, press

 

OFF

.

The call-in/talk indicator for the 
caller turns off.

The ringtone sounds and the call-

in/talk indicators for other calls 
blink red. To answer another call, 
repeat step 

1

 - 

3

.

 Going to the calling 

location directly

Go to the calling location and 

press the reset button for the 

calling station.

The call indicator on the calling 
station and the corresponding 
indicators on the master station  
turn off.

When two or more call indicators 

are lit on a corridor light, 
pressing the reset button turns off 
all the indicators.

NOTES:

Communication will end automatically 

• 

after 90 seconds.

Confi rm the calling station before pressing 

• 

the reset button. The indicators on the 
master station and corridor light will turn 
off when the reset button is pressed. 

Pressing 

• 

OFF

 while talking ends 

the communication and turns off the 
indicators. Be sure to confi rm the calling 
station before pressing 

OFF

There is communication only if a sub 

• 

station or speaker/microphone is installed 
in the calling location.

When a new call comes in during 

• 

communication, the call-in/talk indicator 
for the corresponding station blinks red 
and the ringtone sounds at a low volume.

When you pick up the handset while 

• 

communicating in Push-to-Talk mode, you 
can continue communicating by using the 
handset.

Lights up 

green.

Lights up red.

Turns off.

Station 6

Station 7

Station 8

Station 9

The ringtone sounds.

• 

The call-in/talk indicators for the calling stations blink red.

• 

Up to 10 calls are received on the master station at the same time. 

The 11th and subsequent calls are cancelled.
The call indicators on the stations of the 6th to 10th calls and the 

corresponding corridor lights do not light up.

The corridor light installed at the sub station will light up during call-in.

• 

If the call extension speaker IER-2 is installed, it sounds the same 

• 

ringtone as the master station.

Lights up red while 

sending audio from 

this station to other 

stations.

Summary of Contents for NIM-20B

Page 1: ...our communication needs Please make sure to read this manual for safe and correct use of the system and keep it in a safe place for future reference Please note that images and illustrations depicted...

Page 2: ...USING THE SYSTEM AT THE MASTER STATION 11 Answering a call 11 When receiving a single call 11 When receiving multiple calls 12 Calling sub stations 13 Calling a single sub station 13 Paging 14 Adjusti...

Page 3: ...electric fields GENERAL PRECAUTIONS 1 The unit is inoperative during power failure 2 In areas where broadcasting station antennas are close by this system may be affected by radio frequency interferen...

Page 4: ...North America only Call extension speaker IER 2 Power supply unit IS PU only PC for call log software NI SOFT Corridor light single bed NIR 4 NIR 4 Call reset button NIR 2 NIR 2 Ceiling speaker NI LB...

Page 5: ...ods The following two methods are available on the master station Method Communication style Description Using handset Voice actuated communication The communication mode is VOX half duplex When speak...

Page 6: ...nes audio from a sub station and alarms are heard from here Turn off the POWER switch when the system malfunctions Microphone Sends audio from this station to other stations OFF button OFF Press to en...

Page 7: ...ed Lights up while calling the master station Microphone RECEIVE VOL Adjusts the volume of audio from the master station to 3 levels low mid high Handle Wall jack with hanger for NI RC NIR HPF Hanger...

Page 8: ...hone for NIR 8 NIR MB Call latching wall jack for NIR 8 NIR 7BS Call indicator red Speaker Microphone Wall jack for NIR 8 NIR 1 Bedside call switch NIR 8 Connect and fasten the plug to a wall jack Wal...

Page 9: ...single bed NIR 4 Corridor light multiple beds NIR 4S Call reset button NIR 2 Corridor light with reset button NIR 42 Corridor light with buzzer NIR 4BZ Lamp red Lamp red Reset button Buzzer Pull cord...

Page 10: ...responding sub station Nameplate See below Room number plate See below Lamp red Reset button Corridor light with nameplates 2 names NIR 32 Corridor light with nameplate 1 name NIR 31 Room number plate...

Page 11: ...more call indicators are lit on a corridor light pressing the reset button turns off all the indicators USING THE SYSTEM AT THE MASTER STATION The ringtone sounds The call in talk indicator for the c...

Page 12: ...s the reset button for the calling station The call indicator on the calling station and the corresponding indicators on the master station turn off When two or more call indicators are lit on a corri...

Page 13: ...begin talking NIM system To speak Press and hold TALK while speaking To listen to the user of the sub station Release TALK while listening To end the communication press 3 OFF NIM system The call in t...

Page 14: ...peaking NIM system Do not release TALK until you end speaking A notice sound is heard at all the sub stations To end the paging press 3 OFF NIM system NOTES Paging will end automatically after 90 seco...

Page 15: ...ent communication There is communication only if a sub station or speaker microphone is installed in the calling location While speaking on the master station the TALK indicator is lit audio from the...

Page 16: ...ly after 90 seconds Calling the master station Press the call button 1 The type of call button differs depending on the equipment used in your application When the master station answers begin talking...

Page 17: ...s SPCC Color Panel White Chassis Green mist Dimensions NIM 20B 330 W x 230 H x 140 D mm 13 W x 9 1 16 H x 5 1 2 D NIM 40B 480 W x 230 H x 140 D mm 18 7 8 W x 9 1 16 H x 5 1 2 D 60 call 630 W x 230 H x...

Page 18: ...lbs Bedside call switch NIR 8 Ambient temperature 0 40 C 32 F 104 F Material Plastic Color White Dimensions 36 x 95 H mm 1 7 16 x 3 3 4 H Weight Approx 90g 0 2 lbs Wall jack for NIR 8 NIR 1 Ambient t...

Page 19: ...ht Approx 85g 0 19 lbs Corridor light with reset button NIR 42 Power source Supplied from the master station Ambient temperature 0 40 C 32 F 104 F Mounting Wall flush mount Electrical box 2 gang box M...

Page 20: ...will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products dur...

Reviews: