3
Specification
PERIOD
100ns to 10s (10MHz to 0·1Hz) in 8 overlapping decade ranges, with separate vernier providing
continuously variable control within each range.
Jitter: <0·1%.
PULSE WIDTH
50ns to 5s in 8 overlapping decade ranges, with separate vernier providing continuously variable
control within each range. The Overlap lamp lights when the pulse width is set greater than the
period.
Jitter: <0·1%.
PULSE DELAY
100ns to 5s in 8 overlapping decade ranges, with separate vernier providing continuously
variable control within each range. The overlap lamp lights when the pulse delay is set greater
than the period.
GATED OPERATION
0·1Hz to 10MHz pulse train, parameters set by Period and Pulse Width controls, starts
synchronously with leading edge of Gate input. Last pulse is completed at the end of gating
period.
TRIGGERED OPERATION
DC to 10MHz pulse train in synchronism with external Trigger pulses; pulse width determined by
Pulse Width controls.
DOUBLE PULSE
A second pulse is generated after a delay from the leading edge of the first pulse set by the
Pulse Delay controls.
DELAYED PULSE
The pulse is generated after a delay from the Trigger signal set by the Pulse Delay controls.
SQUAREWAVE
0·1Hz to 10MHz squarewave, frequency set by the Period controls.
Mark:Space ratio typically 1:1 ± 10%.
COMPLEMENT
Inverts both the MAIN (50
Ω)
and AUX outputs.
MANUAL
With Triggered selected:
Pressing Manual initiates a single pulse of duration determined by
the Pulse Width controls.
With Gate selected:
0·1Hz to 10MHz pulse train set by the Period and Pulse Width
controls for the duration of button depression.