4
TRIGGER/GATE IN
Frequency Range:
DC - 10MHz
Signal Range:
Threshold nominally TTL level;
maximum input ±10V.
Trigger Delay:
Typically 100ns from trigger edge to MAIN OUT transition.
Gate Delay:
Approximately 20% of the PERIOD range s80ns from gate leading
edge to MAIN OUT transition.
Minimum Pulse Width:
>30ns.
Input Impedance:
Typically 10k
Ω
.
MAIN 50
Ω
OUTPUT
Amplitude:
Two switch selectable ranges of 0·1V - 1·0V and 1V - 10V from 50
Ω
.
(50mV to 500mV and 500mV to 5V into 50
Ω
). Adjustable within ranges by
a single turn vernier.
V
OUT
low:
<5% of Amp100mV (1V-10V range).
Rise/Fall Times:
Typically 10ns into 50
Ω
load.
Maximum 15ns.
Aberrations:
Typically <5%, for output set at >20% of range maximum, into 50
Ω
.
AUX OUTPUT
CMOS/TTL level, signal with the same timings as MAIN OUT; leads MAIN
OUT by typically 15ns.
SYNC OUTPUT
Amplitude:
A positive going pulse at CMOS/TTL level.
Timing:
Leading edge occurs typically 40ns before the MAIN OUT transition in all
pulse modes and typically 10ns after MAIN OUT in Square mode.
Duration:
Typically 30ns.
GENERAL
Power:
220V-240V or 110V-120V AC ±10%, 50/60Hz, adjustable internally;
20VA max. Installation Category II.
Operating Range:
+ 5°C to 40°C, 20-80% RH.
Storage Range:
-40°C to 70°C.
Environmental:
Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety & EMC:
Complies with EN61010-1 & EN61326-1.
For details, request the EU Declaration of Conformity for this instrument
via http://www.aimtti.com/support (serial no. needed).
Size:
220(W) x 130(H) x 230(D)mm, excluding feet.
Weight:
1·6kg.
Summary of Contents for TGP110
Page 1: ...MODEL TGP110 10MHz Pulse Generator INSTRUCTION MANUAL...
Page 9: ...8...