SAFETY DATA SHEET

HEALTH

PHYSICAL

Acute Toxicity

Aquatic Chronic 1

(Oral/Dermal/Inhalation)

Aquatic Acute 1

HEALTH

ENVIRONMENTAL

PHYSICAL

CAS Number

Components 

Lead

45 - 60

Lead Dioxide

15 - 25

Tin

0.1 - 0.2

Sulfuric Acid Electrolyte (Sulfuric Acid/Water)

15 - 20

Absorbent Glass Mat

1-2

Inorganic lead and sulfuric acid electrolyte are the primary components of every battery manufactured by EnerSys Energy Products. 
There are no mercury or cadmium containing products present in batteries manufactured by EnerSys Energy Products.

 Category 1B

Carcinogenicity (lead compounds)

Explosive, fire, blast, or projection hazard.

Polyphenylene Oxide

25134-01-4

Polycarbonate/Polyester Alloy

--

Other:

--

Styrene Butadiene

9003-55-8

Polyvinylchloride

9002-86-2

Polycarbonate, Hard Rubber, Polyethylene

9002-88-4

Polystyrene

9003-53-6

Styrene Acrylonitrile

9003-54-7

Acrylonitrile Butadiene Styrene

9003-56-9

7440-31-5

7664-93-9

Case Material:

5-10

Polypropylene

9003-07-0

III. HAZARDOUS INGREDIENTS/IDENTIFY INFORMATION

Approximate % by Weight

Inorganic Lead Compound:

7439-92-1

1309-60-0

May form explosive air/gas mixture during charging.

Contact with internal components may cause irritation or severe burns. Avoid contact with internal 

Extremely flammable gas (hydrogen).

Irritating to eyes, respiratory system, and skin.

May damage fertility or the unborn child if ingested or inhaled.

Avoid breathing dust/fume/gas/mist/vapors/spray.

May cause cancer if ingested or inhaled.

Use only outdoors or in a well-ventilated area.

Causes damage to central nervous system, blood and kidneys through prolonged or 
repeated exposure.

Causes skin irritation, serious eye damage.

DANGER!

Wash thoroughly after handling.

Causes severe skin burns and eye damage.

Do not eat, drink or smoke when using this product.

Causes serious eye damage.

Wear protective gloves/protective clothing, eye protection/face protection.

(repeated exposure)

Category 2

GHS LABEL:

Hazard Statements

Precautionary Statements

Reproductive

Category 1A

Carcinogenicity (acid mist)

Category 1A

Specific Target Organ Toxicity

ENVIRONMENTAL

Explosive Chemical, Division 1.3 

Category 4

Skin Corrosion/Irritation

Category 1A

Eye Damage

Category 1

EnerSys Energy Products Inc.
617 N. Ridgeview Drive

24-Hour Emergency Response Contact:

Warrensburg, MO 64093-9301

CHEMTREC DOMESTIC: 800-424-9300 CHEMTREC INT'L: 703-527-3877

II GHS HAZRDS IDENTFICATION

Synonyms:

Sealed Lead Acid Battery, VRLA Battery

Telephone: 

Environmental, Health & Safety Dept. at 660-429-2165

For information and emergencies, contact EnerSys Energy Products

Manufacturer's Name/Address:

 

SAFETY DATA SHEET

I. PRODUCT IDENTIFICATION

Chemical Trade Name (as used on label):

Chemical Family/Classification:

 

Sealed Lead Battery

Cyclon®, Genesis®, SBS, SBS J, Hawker XE™, Odyssey®, Trolling Thunder™, NexSys™, 
OptiGrid™ or XFC

Summary of Contents for PANEL BEATER PB-1000

Page 1: ...ness ai mfg com Website www ai mfg com 1419 N Thierman Road Spokane Valley WA 99212 Tel 800 644 2730 509 244 2730 Fax 509 244 2721 PANEL BEATER TM DENT PULLING MACHINE Operating Instructions Warranty...

Page 2: ...d Warranty Safety Data Sheet 3 3 3 4 5 7 7 8 8 9 9 9 9 10 10 11 11 11 12 12 12 12 13 14 15 16 17 THANK YOU for purchasing an American Innovative Manufacturing Panel Beater TM AIM designs and manufactu...

Page 3: ...need your model and serial number found on the back the unit Model PB 1000 Model PB 1100 Shipped from the factory without Battery Serial Number Purchase Date COMPONENTS Your AIM PANEL BEATER Dent Pull...

Page 4: ...o not touch the copper connectors or electrodes during or immediately after use these components will be HOT WARNING Make sure to use proper PPE when operating Sparks and debris might injure the eyes...

Page 5: ...DES PACK OF 5 PB 113 COPPER SHRINK TOOL CONTROL HANDLE SA 140 WAVE WIRE TIP PB 201 ELECTRODE HOLDER PB 244 SLIDE HAMMER PB 207 PULLER BAR If the item you are looking for is not listed above Visit our...

Page 6: ...WITCH PB 226 Push Button PB 200 CONTROL HANDLE SA 133 1LB WAVE WIRE PB 205 MAGNET ASSEMBLY SA 131 6 FINGER T HANDLE CLAW SHEET 2 OF 2 PARTS LIST PANEL BEATER TM If the item you are looking for is not...

Page 7: ...nsing of battery status and health Multiple charging modes automatically started by sensing battery status Different Charging Modes for Charge maintenance float Extremely low battery Desulfation cycle...

Page 8: ...charged before use INDICATOR LIGHT There is an indicator light displayed on the front panel of the machine SOLID green light indicates the battery is fully charged YELLOW light indicates the battery...

Page 9: ...terTM is designed for 110 120 volt 60 Hz power sources The power requirement for your machine is indicated on the back of your machine NOTE If battery is below 12 5 volts it must be recharged This mac...

Page 10: ...Tighten the nut against the electrode holder to pre vent loosening AIM CONTROL HANDLE The key component of your AIM Dent Puller is the Control Handle In operating the machine you will weld the electr...

Page 11: ...cessary When shrinking Set the timer to the desired setting start with a moderate setting 2 4 Hold the shrinking tip against the panel and depress and hold the control button Do not remove the shrink...

Page 12: ...advanced electronic features designed to prevent over charging the battery and extending battery life The AIM Battery Charger can be operated at the same time the Panel Beater dent pulling machine is...

Page 13: ...as needed 4 STICK Firmly push the electrode tip against the spot to be pulled and push the thumb switch on the electrode handle until it sticks Release after 1 2 seconds 5 PULL Pull straight out firm...

Page 14: ...ARGER 2 YEAR INSPECT BATTERY TERMINAL CONNECTIONS CLEAN IF NEEDED HELPFUL HINTS Not keeping your battery fully charged after use will decrease the life of your battery When dent pulling or shrinking t...

Page 15: ...perating See CHARGING THE UNIT Does grounding need to be placed in a different location Is paint removed from surface Is the electrode touching the metal Check battery with load tester for adequate co...

Page 16: ...he exclusive remedies shall be at AIM s option 1 Repair 2 Replacement 3 The reasonable cost of repair or replacement by an authorized AIM service representative where authorized in writing by AIM in a...

Page 17: ...ng to eyes respiratorysystem and skin Maydamagefertilityortheunbornchild ifingested orinhaled Avoid breathing dust fume gas mist vapors spray Maycausecancerifingested orinhaled Useonlyoutdoors orinawe...

Page 18: ...USE Spill or Leak Procedures Stop flow of material contain absorb small spills with dry sand earth and vermiculite Do not use combustible materials If possible carefully neutralize spilled electro lyt...

Page 19: ...e and face protection when filling charging or handling batteries Do not allow metallic materials to simultaneously contact both the positive and negative terminals of the batteries Charge the batteri...

Page 20: ...ad compounds in the workplace may result in nervous system toxicity Some toxicologists report abnormal conduction velocities in persons with blood lead levels of 50mcg 100 ml or higher Heavy lead expo...

Page 21: ...73 159 f and 49 CFR 173 159a of the U S Department of Transportation s HMR Battery and outer package must be marked NONSPILLABLE or NONSPILLABLE BATTERY Battery terminals must be protected against sho...

Page 22: ...Sulfuric Acid Electrolyte Sulfuric Acid Water 7664 93 9 15 20 Tin 7440 31 5 0 1 0 2 See 40 CFR Part 370 for more details If you distribute this product to other manufacturers in SIC Codes 20 through 3...