background image

Page 9 

Figure 18 –  Apply power and check LED 

Figure 19 – Pan/Tilt Module and Packaging 

Figure 21 – Heater and Safety Wires 

Figure 22 – Attach dome bubble 

Figure 20 – Connect PTZ 
module into Dome Housing 

AMP S ocket

G u id e n o tc h e s

Lo c kin g flan ge s

L o ckin g clip s

Metal Button

LED

Safety line

Heater wire

Heater wire connectors

Captive Screws

 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.4.

 

Pan/Tilt Module Installation 

Remove the pan/tilt module from the packaging and inspect it 
for damage.  If the unit needs to be returned to the factory, 
replace it properly in its packaging as shown in Figure 19. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The PTZ module fits into the dome housing quickly and easily.  
Line up the AMP sockets shown in Figure 20.  The guide 
notches will align the module.  Carefully press the PTZ module 
into position.  Two snaps should be audible as it locks into 
place. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Hold the dome bubble up to the mounted PTZ unit.  If 
installing an outdoor unit, connect the heater ring in the dome 
bubble to the main unit be connecting the heater connectors 
(see Figure 21). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Attach the safety wire from the dome bubble to the main unit 
using the M3x5mm screw provided in the hardware kit. 
 
 
 
Attach the dome bubble to the main unit by securing the four 
captive screws in the trim ring to finish the installation. 
 
 

Summary of Contents for PTZA6 Series

Page 1: ...Page 1 PTZA6 Series Pan Tilt Zoom Domes Installation Manual Aigis Mechtronics Inc 1124 Louise Road Winston Salem NC 27282 Ph 336 785 7740 Fax 336 785 7744 www aigismech com...

Page 2: ...ectrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be wal...

Page 3: ...ce from any high voltage cables or equipment Run outdoor rated cable under building eaves if possible Run cabling to the site in buried sealed steel tubes conduit In areas exposed to the elements shie...

Page 4: ...e unit is shipped in the safest possible packaging Keep it for possible future use If the unit needs to be returned replace it properly in its packaging and contact your supplier for return authorizat...

Page 5: ...as shown in Figure 4 Apply additional sealant to the notch at the base of the mount Position the mount over the wall anchors and begin to tighten the nuts and washers Tighten down the nuts until the a...

Page 6: ...wn in Figure 9 Feed these cables through the back of the wall mount and out through the threaded opening Leave 2 inches of video cable and 3 5 inches of the other cables hanging out of the wall mount...

Page 7: ...nt to the hole in the corner bracket as shown in Figure 11 Select appropriate sized hose clamps for the installation Pass the hose clamps not supplied through the slots in the pole bracket and around...

Page 8: ...ccess panel by pressing the metal button shown in Figure 14 The access panel flips down Do not touch the AMP socket when opening the panel Make the power video data and alarm optional connections insi...

Page 9: ...in its packaging as shown in Figure 19 The PTZ module fits into the dome housing quickly and easily Line up the AMP sockets shown in Figure 20 The guide notches will align the module Carefully press t...

Page 10: ...Contact Aigis for more information 4 1 Ceiling Hole Preparation Draw a circle on the ceiling for the hole the PTZ will be mounted into The dimensions of the hole should be 8 86 in 225mm minimum to 8 9...

Page 11: ...ws see Figure 29 that are attached to the plastic ceiling clips Loosen the screws until the clips are raised off the flange by an amount greater than the ceiling thickness Raise the unit up into the h...

Page 12: ...P sockets shown in Figure 34 The guide notches will align the module Carefully press the PTZ module into position Two snaps should be audible as it locks into place 4 3 Trim Ring and Dome Bubble Attac...

Reviews: