background image

Page 10 

Figure 27 – Cable Connections 

Bulkhead connector 

Figure 24 – Ceiling Hole Dimensions 

Figure 25 – Video, power, data and 
alarm (optional) connectors 

Tightening Cap 

Figure 26 – Recessed housing access panel 

Metal Button

Metal Button

AC Power / Data 
Terminal Block

Alarm Terminal Block

B N C Co nn e ctor

 

4.

 

Recess Mount Installation 

Indoor recess-mount domes can be mounted in drop ceilings 
(a.k.a. ceiling tiles, acoustic ceiling tiles, etc.) or sheetrock 
ceilings.  A typical installation is shown in Figure 23.  The 
ceiling must be able to support 4 times the weight of the PTZ.   
 
 
 
 
 
 
 
 
 
 
 
 
 
Note: an additional support bracket is available (Part Number 
MT-PTZ2X2) that is installed above the ceiling tile and clips on 
to the ceiling tile grid.  The PTZ then clips to both the support 
bracket and the ceiling tile.  Contact Aigis for more 
information. 

4.1.

 

Ceiling Hole Preparation 

Draw a circle on the ceiling for the hole the PTZ will be 
mounted into.  The dimensions of the hole should be 8.86-in 
(225mm) minimum to 8.94-in (227mm) maximum, as shown 
in Figure 24  The unit cannot be installed if the hole is in 
excess of 9.37-in (238mm). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Depending on the type of material, select the appropriate tool 
to cut out the mounting hole.  
 
Run the power, video, data and alarm (optional) cables to the 
site.  Terminate the wires into the connectors provided in the 
hardware kit (see Figure 25).   
 
Remove the tightening cap from the bulkhead connector (see 
Figure 27) on the side of the housing.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Feed all necessary wires through the tightening cap (see 
Figure 25), then through the bulkhead connector and into the 
recessed housing. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Press the metal button shown in Figure 26 to open the access 
panel in order to make the cable connections. 
 
Connect the external cables to the connectors indicated in 
Figure 27. 

Figure 23 – Recess Mount 

Summary of Contents for PTZA6 Series

Page 1: ...Page 1 PTZA6 Series Pan Tilt Zoom Domes Installation Manual Aigis Mechtronics Inc 1124 Louise Road Winston Salem NC 27282 Ph 336 785 7740 Fax 336 785 7744 www aigismech com...

Page 2: ...ectrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be wal...

Page 3: ...ce from any high voltage cables or equipment Run outdoor rated cable under building eaves if possible Run cabling to the site in buried sealed steel tubes conduit In areas exposed to the elements shie...

Page 4: ...e unit is shipped in the safest possible packaging Keep it for possible future use If the unit needs to be returned replace it properly in its packaging and contact your supplier for return authorizat...

Page 5: ...as shown in Figure 4 Apply additional sealant to the notch at the base of the mount Position the mount over the wall anchors and begin to tighten the nuts and washers Tighten down the nuts until the a...

Page 6: ...wn in Figure 9 Feed these cables through the back of the wall mount and out through the threaded opening Leave 2 inches of video cable and 3 5 inches of the other cables hanging out of the wall mount...

Page 7: ...nt to the hole in the corner bracket as shown in Figure 11 Select appropriate sized hose clamps for the installation Pass the hose clamps not supplied through the slots in the pole bracket and around...

Page 8: ...ccess panel by pressing the metal button shown in Figure 14 The access panel flips down Do not touch the AMP socket when opening the panel Make the power video data and alarm optional connections insi...

Page 9: ...in its packaging as shown in Figure 19 The PTZ module fits into the dome housing quickly and easily Line up the AMP sockets shown in Figure 20 The guide notches will align the module Carefully press t...

Page 10: ...Contact Aigis for more information 4 1 Ceiling Hole Preparation Draw a circle on the ceiling for the hole the PTZ will be mounted into The dimensions of the hole should be 8 86 in 225mm minimum to 8 9...

Page 11: ...ws see Figure 29 that are attached to the plastic ceiling clips Loosen the screws until the clips are raised off the flange by an amount greater than the ceiling thickness Raise the unit up into the h...

Page 12: ...P sockets shown in Figure 34 The guide notches will align the module Carefully press the PTZ module into position Two snaps should be audible as it locks into place 4 3 Trim Ring and Dome Bubble Attac...

Reviews: