4.
Recess Mount Installation
Indoor recess-mount domes can be mounted in drop ceilings
(a.k.a. ceiling tiles, acoustic ceiling tiles, etc.) or sheetrock
ceilings. A typical installation is shown in Figure 23. The
ceiling must be able to support 4 times the weight of the PTZ.
Note: an additional support bracket is available (Part Number
MT-PTZ2X2) that is installed above the ceiling tile and clips on
to the ceiling tile grid. The PTZ then clips to both the support
bracket and the ceiling tile. Contact Aigis for more
information.
4.1.
Ceiling Hole Preparation
Draw a circle on the ceiling for the hole the PTZ will be
mounted into. The dimensions of the hole should be 8.86-in
(225mm) minimum to 8.94-in (227mm) maximum, as shown
in Figure 24 The unit cannot be installed if the hole is in
excess of 9.37-in (238mm).
Depending on the type of material, select the appropriate tool
to cut out the mounting hole.
Run the power, video, data and alarm (optional) cables to the
site. Terminate the wires into the connectors provided in the
hardware kit (see Figure 25).
Remove the tightening cap from the bulkhead connector (see
Figure 27) on the side of the housing.
Feed all necessary wires through the tightening cap (see
Figure 25), then through the bulkhead connector and into the
recessed housing.
Press the metal button shown in Figure 26 to open the access
panel in order to make the cable connections.
Connect the external cables to the connectors indicated in
Figure 27.