SBC-6504 User Manual
z
Program Sample
2E, 87
2E, 87
2E, 07
2F, 08
Logical Device 8
2E, 30
Activate
2F, 01
2E, F5
2F, N
Set Minute or Second
N=08 (Min),00(Sec)
2E, F6
2F, M
Set Value
M = 00 ~ FF
Note#:
N=00
M= 00h: Time-out Disable
01h: Time-out occurs after 1 second
02h: Time-out occurs after 2 second
03h: Time-out occurs after 3 second
……………………….......................................
FFh: Time-out occurs after 255 second
N=08
M= 00h: Time-out Disable
01h: Time-out occurs after 1 minute
02h: Time-out occurs after 2 minutes
03h: Time-out occurs after 3 minutes
……………………….......................................
FFh: Time-out occurs after 255 minutes