33
Chapter 3. 2U30 JBOD Subsystem Configuration Settings
Rack Venus User Manual
3.5.7 How to configure wide port checker
This feature is applicable for SAS drives instead of SATA drives. If there is no
connection with any active SAS initiator by checking all wide ports, AIC Expander
Controller stops all attached SAS drives to save power consumption of SAS
drives. Otherwise, AIC Expander Controller starts all attached SAS drives to
provide drive access service to any active SAS initiator. The same setting should
be applied to HUB and EGDE.
(A) Get the current state of wide port checker
cmd> check_wide_port
Checking wide port is OFF
(B) Enable checking wide port. The new setting will take effect after reset.
cmd> check_wide_port on
cmd> reset
(C) Disable checking wide port. The new setting will take effect after reset.
cmd> check_wide_port off
cmd> reset
Summary of Contents for Rack Venus
Page 1: ...UM_Rack Venus_v1_110619 Rack Venus Server Rack User s Manual...
Page 6: ...Document Release History Release Date Version Update Content November 2019 1 Release to public...
Page 39: ...28 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Page 45: ...34 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Page 50: ...39 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Page 138: ...127 Chapter 7 Pavo Serverboard Rack Venus User Manual Launch KVM...