G-18
G-084383_EN • 03
T
echnical
S
pecificaTionS
Combustion and Gas Data
CM 60
(min. - max.)
CM 70
(min. - max.)
CM 80
(min. - max.)
chimney type(s)
B23, B23p, C13, C33, C43, C53, C63, C83, C93
flue gas temperature at 80/60°C
°C
47.9 - 53.8
47.9 - 54.2
47.9 - 55.1
flue gas temperature at 50/30°C
°C
26.4 - 28.3
26.4 - 28.5
26.4 - 28.8
overheat flue gas temperature
°C
110
max. flue gas pressure
(incl. max wind condition)
Pa
190
Max. chimney length (100/150)
m
25
25
25
mass flow rate of flue gases
g/s
26.0
31.6
36.7
max. condensate volume
kg/h
7.1
8.6
10.0
CO emissions
mg/kWh
43.3
CO
2
contents (G20/G25)
%
8.4
(± 0.1)
- 8.8
(+0.2)
CO
2
contents (G31)
%
10.0
(± 0.2)
- 10.5
(± 0.2)
O
2
contents (G20)
%
5.9
(± 0.18)
- 5.2 (
-0.36)
O
2
contents (G25)
%
5.7
(± 0.18)
- 4.9 (
-0.36)
O
2
contents (G31
%
5.7
(± 0.30)
- 4.9
(± 0.30)
NOx level (weighted)
mg/kWh
30.3
NOx class
6
gas type(s)
G20 , G25, G25.3, G31
gas categories
I2E(S,R), I3P, I2E, I2ELL, II2L3P, IIEK3P, II2E3P, II2Esi3P, IIH3P
gas pressure
G20 (20 mbar)
mbar
17 - 25
G25 (25 mbar)
mbar
20 - 30
G25.3 (25 mbar)
mbar
18 - 33
G31 (30/37/50 mbar)
mbar
25.0-35.0 / 25.0-45.0 / 42.5-57.5
gas flow rate (G20)*
m
3
/h
0.98 - 5.99
0.98 - 7.28
0.98 - 8.44
gas flow rate (G25)*
m
3
/h
1.10 - 7.01
1.10 - 8.54
1.10 - 9.76
gas flow rate (G31)*
m
3
/h
0.40 - 2.34
0.40 - 2.84
0.40 - 3.25
*
15°C, 1013.25 mbar, dry gas