background image

Presto Master 

10/11/2016 

Copyright

©

Agricultural Instruments Corp (AIC) 

A message from AIC 

 

Agricultural  Instruments  Corporation  (AIC)  would  like 
to  thank  you  for  purchasing  your  new  Presto  Master 
and  accessories.  The  instrument  you  purchased  will 
be valuable  dairy herd management tool for years to 
come 

 

The  Tracker  Plus  hands-off  dairy  management      
system  networks  with  AIC’s  “Smart  Sensing”  milk  
meters.  With  the  Tracker  Plus  system  is  not          
necessary  to  learn  and  maintain  computer  software 
and  equipment  requiring  large  amounts  of  time  and 
expense.  The  data  is  collected  and  compiled        
automatically and is available instantly at the press of 
a button 
 
This manual lists the technical specifications and is a 
guide  for  installation,  operation  and  service  of  the 
equipment.  
 
It  is  essential  that  all  instructions  in  this  manual  be 
followed  as  prescribe  to  achieve  the  full  benefits  of 
the product as they were designed. 
 
We  would  also  like  to  point  out  that  failure  to  follow 
the  instructions  could  result  in  unsafe    conditions  for 
the operator, livestock and equipment.  

 

 

 

 

 

 

        Disclaimer 

 

The  products  and  information  in  this  catalog  have  been  gathered  from  many  sources  and  every    
effort has been made to present the information accurately and correctly. However, the information 
presented in this catalog is solely for the purpose of identification of the products listed herein and 
does not express or imply a warranty that the products will necessarily conform to the illustrations or 
descriptions  presented  herein.  AGRICULTURAL  INSTRUMENTS  CORPORATION  DISCLAIMS 
MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE  FOR  ALL  PRODUCTS 
LISTED  OR  SHOWN  IN  THIS  CATALOG.  ANY  LIABILITY  OR  CONSEQUENTIAL,  INCIDENTAL, 
PUNITIVE  OR  SPECIAL  DAMAGES  OF  ANY  KIND  IS  DISCLAIMED.  AGRICULTURAL                
INSTRUMENT  CORPORATION’S  LABILITY  SHALL  NOT,  UNDER  ANY  CIRCUMSTANCES,      
EXCEED  THE  AMOUNT  PAID  TO  AGRICULTURAL  INSTRUMENTS  CORPORATION  FOR  ANY 
PRODUCT SOLD THROUGH THIS CATALOG.  

None  of  the  information  presented  in  this  catalog  should  be  used  as  or  substituted  for  the  manufacturer’s    
instruction.  Each  product  of  par  should  be  in  strict  accordance  with  the  manufacturer’s  instructions.  Many 
states  and  localities  have  codes  and  regulations  governing  sales,  construction,  installation  and/or  use  of    
certain products of certain purposes, which may vary from locality to locality. While Agricultural Instruments 
Corporation  attempts  to  assure  that  the  products  in  this  catalog  comply  with  such  codes,  it  guarantee        
compliance  and  is  not responsible  for  how  the product  is  installed  or  used.  Before  purchase,  installation  or 
use  of  any  product,  the  product’s  application  and  instructions  and  all  applicable  national,  state  and  local 
codes  should  be  reviewed  to  ensure  that  the  product,  installation  and  use  thereof  will  comply  with  such      
national, state and local 

codes.  

Summary of Contents for Presto Master

Page 1: ...Presto Master Copyright Agricultural Instruments Corp AIC...

Page 2: ...urpose of identification of the products listed herein and does not express or imply a warranty that the products will necessarily conform to the illustrations or descriptions presented herein AGRICUL...

Page 3: ...petroleum based products to come into contact with the control box or flow cell These products will damage the plastic Power Requirements Power Conversion P power watts I current amps V volts Amps I w...

Page 4: ...more power supplies are used in the same installation the negative outputs must be tied together by adding an 14 gauge jumper wire tying the negative DC outputs together of each power supply This est...

Page 5: ...an udder w milker unit by the right attach detach switch To change any of the operating parameters it is necessary to enter the setup mode To enter into the setup mode push both switches at the same t...

Page 6: ...h Detach Right Side There are three lamps embedded in the top of the control two red and one yellow The two red lamps located on the upper corners of the controls provide indications as follows Right...

Page 7: ...Power Source Presto Master Internal and External Wiring Diagram External Wiring Diagram The following wiring schematics layout three different ways the Analyst Presto Control can be wired USE DIELECT...

Page 8: ...agram 2 conductor 24 gauge or larger cable power directly from Presto system power supply 2 conductor twisted pair of communication cable w shield NOTICE Com Cable from Presto Detacher Control Stall 1...

Page 9: ...or dry the cows are milked They should be adjusted according to the farmers liking To do so during milking immediately after the detacher detachers the milking unit hand strip the cows and with guidan...

Page 10: ...ber when starting milk Take Off Flow Rate 0 2 4 LB min 0 09 1 82 Kg min Varies 0 8 LB min 0 36 Kg min Increase to milk cows wetter decrease to milk cows drier Detach Delay 0 60 seconds 1 second 10 sec...

Page 11: ...ure CT Logic Deviation Degrees 3 5 9 Degrees 1 6 Degrees The deviation degree is the amount the milk temperature must deviate from the average to set off the high temp alarm Alarm Temp De grees F or C...

Page 12: ...imer The timer starts when milk switch is pressed The Presto display shows a countdown to attach Power Up Mode Memory Idle Wash Memory Memory the Presto Control will power up in the mode it was last p...

Page 13: ...re two switches embedded in the decal on the front cover of the Presto Master They are pictorially labeled with a hand for manual left switch and udder w milking unit for milking right switch The foll...

Page 14: ...mber of Cows Milked PR Prep Ratio TM Average Milking Time Per Cow Next Takes you to the next screen CPH Cows Per Hour ALL All the Cows Switching this will show you individual group numbers Screen Curr...

Page 15: ...Average Milking Time Per Cow Next Takes you to the next screen CPH Cows Per Hour ALL All the Cows Switching this will show you individual group numbers Screen Currently In TL CT PR TM Next CPH ALL TL...

Page 16: ...the flow cell The timer begins when the operator has activated the right switch and the Presto Control enters milking mode The milking timer will stop when the detach milk flow threshold has been dete...

Page 17: ...sent from the Presto Master to the detachers and is not received back Possible cable or electrical damage NACK No Acknowledge Stall control does not acknowledge data sent by Presto Master within allo...

Page 18: ...part must be returned for warranty consideration This Warranty extends only to the original purchaser and may not be transferred It is valid only on the original installation unless the Company otherw...

Page 19: ...n Each product of par should be in strict accor dance with the manufacturer s instructions Many states and localities have codes and regulations governing sales construction installation and or use of...

Page 20: ...D Number Yes No N A Presto units will ask for an IC Number when starting milk Take Off Flow Rate 0 2 4 LB min 0 09 1 82 Kg min Varies Increase to milk cows wetter decrease to milk cows drier Detach De...

Page 21: ...alarm threshold Invert Shutoff Yes No Reverses polarity to vacuum shut off shifting valve Invert Cylinder Yes No Reverses polarity to retraction cylinder shifting valve PWM Yes ON No OFF Power Modulat...

Page 22: ...powers up the detach mode Wash The Presto Control will power up in wash mode Reset Factory Defaults Yes No Selecting Reset factory default will reset all your settings Switching the settings back to t...