Function 

Range 

Increments 

User  

Settings 

Effects of  

Adjustment 

Vacuum on Delay 

0 - 2.5       sec-

onds 

0.5 seconds 

 

Delay to apply vacuum after releasing cylinder 

Calibrate meters to 

read higher or lower 

-15 to +15 

 

Increase if Analyst over reads. Use left/right 

switch to move over the marker 

Conductivity      Sen-

sitivity Offset 

-30 to 30 

 

 Increase to make less sensitive, decrease to 

make more sensitive 

Use CT Logic 

Yes / No 

 

 

Yes Enables CT Critical Temperature Logic, No 

Skips CT Logic and reverts to a fixed            

temperature alarm 

When CT Logic is 

Yes 

CT Logic Average 

4,8 or 16 

 

 

The number of cow milk temperatures that are 

averaged. The average is       considered the nor-

mal milk temperature 

CT Logic Deviation 

Degrees 

.3 - 5.9      De-

grees 

 

 

The deviation degree is the amount the milk   

temperature must deviate from the average to set

-off the high temp alarm 

Alarm Temp.     De-

grees F or C 

100° - 108° F 

37.7° - 42.2°C 

0.2° F 

0.1° C 

 

Adjust milk Temperature alarm      threshold 

Invert Shutoff 

Yes / No 

 

 

Reverses polarity to vacuum shut-off shifting 

valve 

Invert Cylinder 

Yes / No 

 

 

Reverses polarity to retraction cylinder shifting 

valve 

PWM 

Yes = ON 

No = OFF 

 

 

Power Modulation Output to shifting valves,  

reduces output voltage for 1/2 after a full output 

for 400 milliseconds 

Parlor Type 

 

Low Line 

High Line 

 

Setup to match milk pipeline type 

 

Wash Temperature 

109.4° - 130°F 

43° - 54.4° C 

 

 

The was temperature threshold the Presto       

detacher recognizes and times how long the wash 

temperature is above this temperature 

Password 

Yes / No 

 

 

Add password protection to the setup menu 

Continue Revert to 

Auto 

Yes / No 

 

 

Yes makes the unit automatically switch to    

automatic sensing when “Continue” is pressed 

Attach / Prep Timer 

0 - 180      sec-

onds 

5 seconds 

 

Zero disables the prep timer. The timer starts 

when the detacher milk (right) switch is pressed. 

The Presto display shows a countdown number 

to zero with it is time to attach. Ten seconds 

prior to actual attach time, the red lights flash, 

providing a visual signal that it is time to attach 

the milking unit. Zero disables the prep timer. 

The timer starts when milk switch is pressed. 

The Presto display shows a countdown to attach. 

Summary of Contents for Presto Master

Page 1: ...Presto Master Copyright Agricultural Instruments Corp AIC...

Page 2: ...urpose of identification of the products listed herein and does not express or imply a warranty that the products will necessarily conform to the illustrations or descriptions presented herein AGRICUL...

Page 3: ...petroleum based products to come into contact with the control box or flow cell These products will damage the plastic Power Requirements Power Conversion P power watts I current amps V volts Amps I w...

Page 4: ...more power supplies are used in the same installation the negative outputs must be tied together by adding an 14 gauge jumper wire tying the negative DC outputs together of each power supply This est...

Page 5: ...an udder w milker unit by the right attach detach switch To change any of the operating parameters it is necessary to enter the setup mode To enter into the setup mode push both switches at the same t...

Page 6: ...h Detach Right Side There are three lamps embedded in the top of the control two red and one yellow The two red lamps located on the upper corners of the controls provide indications as follows Right...

Page 7: ...Power Source Presto Master Internal and External Wiring Diagram External Wiring Diagram The following wiring schematics layout three different ways the Analyst Presto Control can be wired USE DIELECT...

Page 8: ...agram 2 conductor 24 gauge or larger cable power directly from Presto system power supply 2 conductor twisted pair of communication cable w shield NOTICE Com Cable from Presto Detacher Control Stall 1...

Page 9: ...or dry the cows are milked They should be adjusted according to the farmers liking To do so during milking immediately after the detacher detachers the milking unit hand strip the cows and with guidan...

Page 10: ...ber when starting milk Take Off Flow Rate 0 2 4 LB min 0 09 1 82 Kg min Varies 0 8 LB min 0 36 Kg min Increase to milk cows wetter decrease to milk cows drier Detach Delay 0 60 seconds 1 second 10 sec...

Page 11: ...ure CT Logic Deviation Degrees 3 5 9 Degrees 1 6 Degrees The deviation degree is the amount the milk temperature must deviate from the average to set off the high temp alarm Alarm Temp De grees F or C...

Page 12: ...imer The timer starts when milk switch is pressed The Presto display shows a countdown to attach Power Up Mode Memory Idle Wash Memory Memory the Presto Control will power up in the mode it was last p...

Page 13: ...re two switches embedded in the decal on the front cover of the Presto Master They are pictorially labeled with a hand for manual left switch and udder w milking unit for milking right switch The foll...

Page 14: ...mber of Cows Milked PR Prep Ratio TM Average Milking Time Per Cow Next Takes you to the next screen CPH Cows Per Hour ALL All the Cows Switching this will show you individual group numbers Screen Curr...

Page 15: ...Average Milking Time Per Cow Next Takes you to the next screen CPH Cows Per Hour ALL All the Cows Switching this will show you individual group numbers Screen Currently In TL CT PR TM Next CPH ALL TL...

Page 16: ...the flow cell The timer begins when the operator has activated the right switch and the Presto Control enters milking mode The milking timer will stop when the detach milk flow threshold has been dete...

Page 17: ...sent from the Presto Master to the detachers and is not received back Possible cable or electrical damage NACK No Acknowledge Stall control does not acknowledge data sent by Presto Master within allo...

Page 18: ...part must be returned for warranty consideration This Warranty extends only to the original purchaser and may not be transferred It is valid only on the original installation unless the Company otherw...

Page 19: ...n Each product of par should be in strict accor dance with the manufacturer s instructions Many states and localities have codes and regulations governing sales construction installation and or use of...

Page 20: ...D Number Yes No N A Presto units will ask for an IC Number when starting milk Take Off Flow Rate 0 2 4 LB min 0 09 1 82 Kg min Varies Increase to milk cows wetter decrease to milk cows drier Detach De...

Page 21: ...alarm threshold Invert Shutoff Yes No Reverses polarity to vacuum shut off shifting valve Invert Cylinder Yes No Reverses polarity to retraction cylinder shifting valve PWM Yes ON No OFF Power Modulat...

Page 22: ...powers up the detach mode Wash The Presto Control will power up in wash mode Reset Factory Defaults Yes No Selecting Reset factory default will reset all your settings Switching the settings back to t...