trolled by the HPPH control. These include: (1) 3-way
valve control (Yes or No), (2) Pump control (Yes or No
and then what type of control – 4-speed control or vari-
able speed control), and (3) Auxiliary control (Yes or
No and then what type – External Heat, Auxiliary
Output or Remote Output).
Once these choices are made, then additional infor-
mation relating to the establishing of pump periods,
pump speeds during each period and Return/Suction
Valve positions during each period must be deter-
mined and set in the control.
The options for the control can be very simple or very
detailed, depending upon each installation desires.
Once programming is completed, the control is ready
for operation.
The user may select one of several operating modes
since these units are HEAT/COOL models. Each
mode is selected by pressing the MENU button to
cycle between the modes. Each press of the MENU
button selects the next mode. There is no automatic
increment from continually pressing the MENU button.
In fact, continually pressing the MENU button (for 3+
seconds) will move the user into the USER Menu.
USER MODES
For HEAT/COOL models, the mode selections are:
OFF – POOL HEAT – POOL COOL – POOL AUTO
– SPA – TIMED SPA.
On HEAT/COOL models, there are additional opera-
tional modes available as noted below:
1. When POOL HEAT mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool heating setpoint temperature.
Holding the UP or DOWN buttons down will speed
up the change of the temperature values.
2. When POOL COOL mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool cooling setpoint temperature.
Holding the UP or DOWN buttons down will speed
up the change of the temperature values.
3. When POOL AUTO mode is selected, each press
of the UP or DOWN buttons will increase /
decrease the pool setpoint temperature. Holding
the UP or DOWN buttons down will speed up the
change of the temperature values.
4. When SPA mode is selected, each press of the UP
or DOWN buttons will increase / decrease the spa
setpoint temperature. Holding the UP or DOWN
buttons down will speed up the change of the tem-
perature values.
5. When TIMED SPA mode is selected, the display
will read “Up or Dn to Set”. This tells the user to
press the UP or DOWN buttons to set the desired
timer for timed SPA heating operation. Pressing
the UP button will increase the timer in 15 minute
increments (up to a total of 6 hours). Pressing the
DOWN button will decrease the timer by 15 minute
increments. The timer will start and the unit will
begin heating as necessary to maintain the Spa
setpoint temperature for this duration. At the end of
the timed period, the unit will automatically go to
the last operational state (POOL HEAT, POOL
COOL, POOL AUTO, or OFF). Once the unit turns
on, the display will toggle between the current Spa
water temperature and the current operating state
“Heating” for example. Pressing the MENU button
will change the display to show the time remaining
on the timer. Press the MENU button again to go
back to the current status.
The control saves the setpoint changes in non-volatile
memory and begins using them for heat demand dec-
sions after both the UP and DOWN buttons have been
released for 2+ seconds.
REMOTE Mode is accessed by pressing and holding
the UP and DOWN buttons simultaneously for 3 sec-
onds. When exiting the REMOTE mode, the control
always selects the OFF Mode.
If the UP, DOWN or MENU buttons are pressed while
in REMOTE mode, the display will read “Exit Remote
Mode to Adjust Temp”. Mode and temperature set-
points are not changed. Press and hold the UP and
DOWN buttons for 3 seconds to exit REMOTE Mode.
The INSTALLER/SERVICE menu can be accessed by
pressing and holding the UP and MENU buttons for 3+
seconds. The INSTALLER/SERVICE menu does not
affect operation of the unit which continues to operate
in the background. When in this mode, pressing the
UP or DOWN buttons will toggle through the various
information reported. Some items (Fault History and
Sensor Temperatures) have multiple values (press UP
or DOWN buttons to scroll through the additional infor-
mation. The INSTALLER/SERVICE menu may be
exited to return to the previous display be pressing the
UP and MENU buttons or it will automatically be exited
if no button is pressed within 60 seconds.
NOTE:
Setpoints are not adjustable while in the
OFF mode or if the Control Lock Box mode is active.
11
Summary of Contents for 9350HC
Page 8: ...8 Fig 2 Hurricane Tie Down Instructions ...
Page 31: ...31 Fig 9 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater ...
Page 34: ...34 Wiring Diagram 208V 230V Three Phase Digital Models ...
Page 35: ...35 Wiring Diagram 460V Three Phase Digital Models 460V 3PH 60 Hz ...
Page 36: ...36 Wiring Diagram 380V Three Phase Digital Models ...
Page 39: ...39 ...