28
Error Message
Description
Troubleshooting
Control Fault 7
Interrupt Error.
Auto reset in 1 hour or Recycle control – replace control if fault
continues.
Control Fault 8
Time of Day Clock Failure.
If the control is unable to read the time of day clock, it logs the
fault and disables scheduled pump and aux output settings.
Time is displayed as ??:?? in this condition. Recycle control –
replace control if fault continues.
Service Call Verification
Before you make a service call,
first
determine if the
problem is:
• Warranty Service - must have model number, seri-
al number and date of installation.
• Unit operation (power supply, water flow, or time
clock adjustment)
Power Supply
• Verify that all circuit breakers are reset and work-
ing properly.
• If the temperature display on the control panel still
does not light, contact the installing dealer, since it
may be a power problem requiring an electrician.
Water Flow
• Verify that the pool filter is clean to provide good
flow.
NOTE:
The
MANUFACTURER IS NOT RESPON-
SIBLE
for these adjustments.
NOTE:
Previous settings will be erased and are no
longer recoverable. All settings will have to re-
entered by hand to re-establish proper operation.
NOTE:
The Raypak Service number is
800-260-
2758.
• Verify that valves are properly positioned to allow
adequate water flow through the unit.
Time Clock Adjustment
Verify that the time clock is set to permit the unit to run
long enough to heat properly.
Set Factory Defaults
If programming is messed up and no operation can
reliably be made, the control board can be reset to
Factory Default values as noted in Table D. This oper-
ation changes all adjustable settings to factory default
settings.
Enter the Installer/Service Mode by holding the MENU
and UP buttons for 3+ seconds. Scroll through the
information until you reach the "Installer Menu" screen
- press the UP or DOWN button until YES appears on
the 2nd line. Press the MENU button to access the
additional Service information. Continue to press the
MENU button until "Set Factory Defaults" appears on
the display. Press and hold the UP and DOWN button
for 5 seconds to reset the control to factory defaults.
The display will read "Defaults Set" when completed.
Summary of Contents for 9350HC
Page 8: ...8 Fig 2 Hurricane Tie Down Instructions ...
Page 31: ...31 Fig 9 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater ...
Page 34: ...34 Wiring Diagram 208V 230V Three Phase Digital Models ...
Page 35: ...35 Wiring Diagram 460V Three Phase Digital Models 460V 3PH 60 Hz ...
Page 36: ...36 Wiring Diagram 380V Three Phase Digital Models ...
Page 39: ...39 ...