13
Item
Range
Default
Value
Access Level
Description
Pump Speed 2
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Return Valve 2
Pool/Spa
Pool
User
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 2
Pool/Spa
Pool
User
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 3
12:00A–11:59P
---
User
Select ON time for Pump Period #3 to
take effect.
Pump Off Time 3
12:00A–11:59P
---
User
Select OFF time for Pump Period #3
to stop.
Pump Speed 3
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Return Valve 3
Pool/Spa
Pool
User
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 3
PoolSpa
Pool
User
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 4
12:00A–11:59P
---
User
Select ON time for Pump Period #4 to
take effect.
Pump Off Time 4
12:00A–11:59P
---
User
Select OFF time for Pump Period #4
to stop.
Pump Speed 4
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Return Valve 4
Pool/Spa
Pool
User
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 4
Pool/Spa
Pool
User
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
NOTE:
Make sure that the values for each setting are recorded for future reference or if the control ever needs
to be reset to Factory Defaults. All these values will need to be re-entered.
Summary of Contents for 9350HC
Page 8: ...8 Fig 2 Hurricane Tie Down Instructions ...
Page 31: ...31 Fig 9 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater ...
Page 34: ...34 Wiring Diagram 208V 230V Three Phase Digital Models ...
Page 35: ...35 Wiring Diagram 460V Three Phase Digital Models 460V 3PH 60 Hz ...
Page 36: ...36 Wiring Diagram 380V Three Phase Digital Models ...
Page 39: ...39 ...