INSTRUCTIONS FOR USE
AGP 1000 – 2000 PRO
Rev.02/2019
49
10.4.4
The PR9 electric motor operated control valve
Figure 10.7
The electric motor operated control valve for
automatic pressure adjustment is an integral
part of the PR9 high pressure regulator.
10.4.5
Pressure filter
Figure 10.8
The PR8 and PR9 pressure regulators feature
a robust and sturdy high-pressure filter. The
filter contains a stainless steel mesh filter
insert with a standard density of 80 MESH
(yellow). The filter density level is indicated
by a colour marking at the top of the filter.
Because the filter is not only used for
filtering, it must be occasionally opened and
cleaned.
If powder-based spraying agents are used, it
is recommended to clean the filter insert
before every spraying to ensure uninterrupted
spraying..