INSTRUCTIONS FOR USE
AGP 1000 – 2000 PRO
Rev.02/2019
41
8.1.2
Complete cleaning
Complete cleaning of the mist blower includes the cleaning of all interior parts, consisting of the
main reservoir (1 - Figure 8.1), suction filter (18 - Figure 8.1), pump (3 - Figure 8.1), pressure
regulator (14 - Figure 8.1) and nozzles (6 - Figure 8.1).
The lever of the three-way valve (16 - Figure 8.1) must be adjusted so that the flow from the
washing reservoir is open (2 - Figure 8.1). Make sure that the mixing nozzle supply valve (21 -
Figure 8.1) and the valve for reservoir washing nozzles (20 - Figure 8.1) on the pump are both
open. The flow into the main reservoir through the pressure regulator and three-way valve (17 -
Figure 8.1) must be open.
After pumping the water from the washing tank, move the lever of the three-way valve (16 - Figure
8.1) to the position for pumping from the main reservoir and then completely drain the main
reservoir through the nozzles on the spraying tubes by opening the diverter valve (11 - Figure 8.1.
8.1.3
Partial cleaning
Partial cleaning of the machine includes the cleaning of the suction filter (18 - Figure 8.1), the
pump (3 - Figure 8.1), the pressure regulator (14 - Figure 8.1), the distribution cube (7 - Figure
8.1) and the nozzles (6 - Figure 8.1) without changing the concentration of spray in the main
reservoir.
Turn the three-way valve (16 - Figure 8.1) towards the rinsing tank (2 - Figure 8.1) and redirect
the flow directly to the pump (3 - Figure 8.1) with the selector valve (17 - Figure 8.1). Close the
mixing valve on the pump (21 - Figure 8.1) Clean water flows through the filter (18 - Figure 8.1),
the pump, the pressure regulator (14 - Figure 8.1) and open valves (11 - Figure 8.1) and finally
through the spraying nozzles. The amount of spraying agent in the main reservoir remains the
same).