9.7
SUCTION FILTER
The suction filter is mounted between the reservoir and the pump. Its function is to filtrate the
insecticide before it reaches the regulator. The size of the filter is 50 MASH.
FILTER INSERT CLEANING (SUCTION FILTER)
First, unscrew the yellow plug (3) on
the filter lid (2) in counterclockwise
direction and pull it out. The
incorporated stop valve in the filter
blocks the fluid inflow from the main
tank. Unscrew the Holland nut (5) on
the filter lid and the filter insert (4).
Clean the filter insert and assemble the
filter in reverse order.
When assembling the filter make sure that the stop valve metal needle, placed in the pull-out part (with
the yellow plug), is correctly inserted, otherwise the filter will not operate correctly.
WARNING:
When cleaning the filter always wear protective gloves!
Clean the filter insert before each tank filling.
9.8
NOZZLE FOR CLEANING the main tank interior
The nozzle is located inside the main tank and is designed for
washing the interior of the main tank after the spraying is
finished. It is connected to one of the water supply ball valves
mounted on the pump, which supplies the water necessary for
cleaning the tank when the valve is opened.
The nozzle shown in the picture is symbolic and may differ
from the actual configuration of the machine.