    System Function                                                                                           

 

Directly connected to the solar panels (do not need to connect the battery)

 

Using  precise  MPPT  function,  APL  functions,  the  inverter  automatically  adjust  the  solar  panels  of 

maximum output power

simply connect the solar panel to the grid inverters. Do not need to connect 

the battery.

 

 

AC 0 angle with high precision auto-detection

 

AC phase angle of 0 through isolation amplifier then input to the MCU for high-precision detection and 

analysis. The phase shift rate is less than 1%, thus achieve high-precision with phase modulation AC 

output together. 

 

Synchronous High-frequency Modulation 

In the process of the grid, usually adapt the same phase angle in parallel. (ie, When the two-phase 

alternating current total is equal to 0.Use switch to combination the two AC fusion) and the product is 

rectified AC half-frequency AC to 100Hz first, then the machine use the high frequency current in the 

circuit and semi-100Hz frequency alternating current generated combination, to achieve 

high-frequency modulation. 

 

Pure Sine Wave Output 

Use SPWM directly to make pure sine wave output.

 

 

Automatic Sensing Function Solar Luminosity 

Use the latest luminosity perception operation technology. The different illuminate angle and intensity 

of  the  solar  panel  will  produce  different  current  output.  Use  advanced  CPU  to  operate  the  different 

illuminance and the data can be directly displayed on the LCD. Then you can visually see the sense of 

the strength of the sun unit. Used more convenient. 

 

Power Automatically Locked (APL) 

In different current fluctuations, we should use the MPPT function. When the MPPT function adjusted 

to the maximum power point, the product automatically powers locked in maximum power point, then 

made the output power more stable. 

 

Maximum Power Point Tracking (MPPT) 

Because the current intensity and the voltage changes at any time, if there is no power point tracking, 

there will be a lot of problems. In the past time, usually adopt a solar controller, but this product uses 

high-precision MPPT operation power, automatic and immediate adjust the solar panels output power 

at the maximum output point, then achieve a stable output purposes. 

 

Automatically Adapt To Different Load Power Factor

 

Adapt to any of the power load. 

 

Constant Current, Constant Power

 

This  product  is  constant  current,  constant  output  power,  without  any  overload,  over-current 

phenomenon. 

 

Automatically Shut Down When The Power Output Of a Fault

 

When the city power system is in failure, the inverter will automatically turn off the output. 

 

 Current Limit Protection 

        Current limit

 

 

Stack Multiple Machines 

 

       

Multiple small power inverters in parallel can achieve large output power.

 

 

High-Frequency High Conversion Rate

 

Adapt high frequency converter, the output more efficient. 

 

 

Summary of Contents for 200W

Page 1: ... 1 GTI Grid Series 1 GTI Series Inverters For Grid User Manual ...

Page 2: ...uce different current output Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD Then you can visually see the sense of the strength of the sun unit Used more convenient Power Automatically Locked APL In different current fluctuations we should use the MPPT function When the MPPT function adjusted to the maximum power point the product automatica...

Page 3: ...HDIAC 5 Phase 1 Islanding protection VAC f AC Output short circuit protection Current limiting Show LED Installation Wall hanging Cooling Fan Standby Power 1W Night Power 1W Ambient temperature range 25 60 Humidity 0 99 Indoor Type Design Waterproof Indoor Type Design Electromagnetic Compatibility EN50081 part1 EN50082 part1 Power System Disturbance EN61000 3 2 EN60950 1 Network test DIN VDE 1026 ...

Page 4: ...r panel to inverter then make some loss F There must be a circuit breaker between solar power generation and power grid show like the switch A in figure 1 And there will be no load before the circuit breaker G Before connect all the connections you must disconnect the utility power After make sure the all connections are right then connect the utility power H If you need to disconnect the mains sw...

Page 5: ...sure both of the terminal are connect fastness to avoid bad contact Show like figure 3 Figure 3 4 Operation After all connection first open the mains switch then open the inverter When the inverter s green LED shows it means the inverter start to work 5 Several or many inverters used in parallel In order to achieve higher power we can use this inverter in stack For example 4 pcs of 300W grid tie i...

Page 6: ... 6 GTI Grid Series 6 Show as figure 4 Figure 4 6 Single phase connection Connection electrical diagram of the solar inverter used in single phase power generation system show as below ...

Page 7: ... 7 GTI Grid Series 7 7 Three phase connection Connection electrical diagram of the micro inverter used in three phase generation system show below ...

Page 8: ...ge protection Input DC voltage is greater than 28 5VDC 3 Over temperature protection when the chassis temperature is above 75 the temperature dropped about 2 10 minutes to restart automatically after cooling 4 Fault Protection when 110VAC or 220VAC power outage or shutdown 5 Islanding protection When the electric supply stop the inverter automatically shut down output B Green LED 1 Green LED flash...

Reviews: