GTI Grid Series

 

 

   

Parameter Table                                                                                                               

 

Grid-series models 

200W 

300W 

400W 

500W 

600W 

800W 

1000W 

Recommend use solar panels 

320Wp 

420Wp 

520Wp 

620Wp 

720Wp 

1050Wp 

1250Wp 

DC Maximum Input Power 

300W 

400W 

500W 

600W 

700W 

900W 

1200W 

DC maximum voltage 

VpvDC30.2VDC 

DC voltage range 

Vpv 10.5V~28VDC 

Maximum output power factor 

99% 

Maximum input current 

15A 

20A 

25A 

30A 

40A 

45A 

65A 

AC output power 

200W 

300W 

400W 

500W 

600W 

800W 

1000W 

AC maximum output power 

200W 

300W 

400W 

500W 

600W 

1000W 

Anti-voltage protection 

Fuse 

AC standard voltage range 

90~140VAC/180~260VAC 

AC frequency range 

55Hz~63Hz/ 45Hz-53Hz 

Output current total   

harmonic distortion 

THDIAC <5% 

Phase 

<1% 

Islanding protection 

VAC;f AC 

Output short circuit protection 

  Current-limiting 

Show 

  LED 

Installation 

Wall hanging 

Cooling 

Fan 

Standby Power 

<1W 

Night Power 

<1W 

Ambient temperature range 

-25 

~60

 

Humidity 

0~99%(Indoor Type Design) 

Waterproof 

Indoor Type Design 

Electromagnetic Compatibility 

EN50081.part1      EN50082.part1 

Power System Disturbance 

EN61000-3-2    EN60950-1 

Network test 

DIN VDE 1026 

Certificate 

CE 

 

  Packing and weight                                                                                                   

 

N

0.77kg

200-300W

 

1.3kg(400—600W) 

2.1kg(800—1000W) 

G

1.15kg

200—300W

 

1.8kg(400—600W) 

2.6kg(800—1000W) 

Size (L x W x H)  18.7 x 12.6 x 5.1 cm 

21 x 16.5 x 5.3cm 

31 x 16.5 x 5.5cm 

Packing 

(L x W x H)CM 

Inner box: 27x19.5 x 9.5

1PCS

 

Outer box: 49.5x28.5x 40.5

10PCS

 

Inner box: 30.5x21x11.5

1PCS

 

Outer box: 43x32x38

6PCS

 

Inner box: 39.5x 21x11.5

1PCS

 

Outer box: 42.5x41x26.5

4PCS

 

G

W

Outer box

 13.0KG 

11.0KG 

11.0KG 

 

Summary of Contents for 200W

Page 1: ... 1 GTI Grid Series 1 GTI Series Inverters For Grid User Manual ...

Page 2: ...uce different current output Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD Then you can visually see the sense of the strength of the sun unit Used more convenient Power Automatically Locked APL In different current fluctuations we should use the MPPT function When the MPPT function adjusted to the maximum power point the product automatica...

Page 3: ...HDIAC 5 Phase 1 Islanding protection VAC f AC Output short circuit protection Current limiting Show LED Installation Wall hanging Cooling Fan Standby Power 1W Night Power 1W Ambient temperature range 25 60 Humidity 0 99 Indoor Type Design Waterproof Indoor Type Design Electromagnetic Compatibility EN50081 part1 EN50082 part1 Power System Disturbance EN61000 3 2 EN60950 1 Network test DIN VDE 1026 ...

Page 4: ...r panel to inverter then make some loss F There must be a circuit breaker between solar power generation and power grid show like the switch A in figure 1 And there will be no load before the circuit breaker G Before connect all the connections you must disconnect the utility power After make sure the all connections are right then connect the utility power H If you need to disconnect the mains sw...

Page 5: ...sure both of the terminal are connect fastness to avoid bad contact Show like figure 3 Figure 3 4 Operation After all connection first open the mains switch then open the inverter When the inverter s green LED shows it means the inverter start to work 5 Several or many inverters used in parallel In order to achieve higher power we can use this inverter in stack For example 4 pcs of 300W grid tie i...

Page 6: ... 6 GTI Grid Series 6 Show as figure 4 Figure 4 6 Single phase connection Connection electrical diagram of the solar inverter used in single phase power generation system show as below ...

Page 7: ... 7 GTI Grid Series 7 7 Three phase connection Connection electrical diagram of the micro inverter used in three phase generation system show below ...

Page 8: ...ge protection Input DC voltage is greater than 28 5VDC 3 Over temperature protection when the chassis temperature is above 75 the temperature dropped about 2 10 minutes to restart automatically after cooling 4 Fault Protection when 110VAC or 220VAC power outage or shutdown 5 Islanding protection When the electric supply stop the inverter automatically shut down output B Green LED 1 Green LED flash...

Reviews: