TABLE 3-1. TROUBLESHOOTING
MALFUNCTION
PROBABLE CAUSE/ TEST/
INSPECTION
CORRECTIVE ACTION
Goggles fails to
activate.
Batteries are dead, missing or
improperly installed.
Replace the batteries or install it
correctly.
Battery contact surfaces or
contact springs are dirty or
corroded.
Clean the contact surfaces with a
pencil eraser and/ or alcohol and
cotton swabs.
Defective image intensifier.
Please contact Customer Support.
IR illuminator fails to
activate.
Turn the IR illuminator on in a
dark area. Visually estimate
whether or not the observed
scene is illuminated.
If the IR illuminator fails to activate,
please contact Customer Support.
LED indicators fail to
activate.
Visual inspection.
Please contact Customer Support.
Poor image quality.
Check objective lens or
eyepieces focus.
Refocus the lens.
Check for fogging or dirt on
the lenses.
Clean the lenses as detailed in Part
3.1. If image quality is still poor, please
contact Customer Support.
Damaged optical components. Please contact Customer Support
Light is visible
around the eyecup.
Check the eye-relief distance.
Readjust for proper eye-relief
distance.
Check the eyecup resilience.
If the eyecup is defective, please
contact Customer Support.
Focusing ring cannot
be moved.
Check to see if the focusing
ring is bent or broken.
If damaged, please contact Customer
Support.
Eyepiece ring cannot
be moved.
Check to see if the eyepiece
ring is bent or broken.
If damaged, please contact Customer
Support.
3.3 PREPARATION FOR EXTENDED STORAGE
1. Unscrew the battery cap and remove the batteries from the goggles.
2. Inspect the battery compartment for corrosion or moisture. Clean and dry if necessary.
3. Replace the battery cap.
4. Remove the unit from the headgear or helmet mount, if installed.
NOTE:
Prior to placing the Wolf-7 PRO and its accessories into the carrying case, ensure that the goggles
and case are free of dirt, dust, and moisture.
5. Place the goggles and accessories into the carrying case.