14
Chapter 2
Transmit Power Measurements
Configuring the Measurement System
Configuring the Measurement System
The BTS under test have to be set to transmit the RF power remotely through the
system controller. This transmitting signal is connected to the analyzer RF input
port. Connect the equipment as shown.
Figure 2-1
Transmit Power Measurement System
1. Using the appropriate cables, attenuator and adapters, connect the output signal
of the BTS to the RF input of the analyzer.
2. Connect a BNC cable between the frequency reference port of the BTS and the
EXT REF IN port of the analyzer.
3. Connect the Trigger Out from the BTS to the TRIGGER1 IN port of the
analyzer.
4. Connect the system controller to the BTS through the serial bus cable to control
the BTS operation.