Agilent Technologies N5340A Installation Manual Download Page 21

Installing OBSAI Protocol Tester

3

Installation Guide

21

 

To remove legacy components, do the following:

a

Click 

Yes

. The uninstallation process starts. Once this process ends, 

the Uninstall Complete screen of the wizard appears.

b

Click 

Finish

.

This takes you back to the Install System Protocol Tester Software page.

5

Repeat Steps 3 and 4.

This time, the welcome screen of the installation wizard appears.

6

Click 

Next

.

The License Agreement screen appears. 

7

Select 

I accept the terms of the license agreement

.

8

Click 

Next

.

The Setup Type screen appears. This screen prompts you to select the 
setup type that best suits your need.

9

Select one of the following options:

a

Client (GUI only)

: Select if you want to install only the Client 

software on your PC.

b

Cont Client (Full)

:

 

Select

 

if you want to install both the 

Controller and Client software on your PC.

10

Click 

Next

.

The Ready to Install the Program screen appears.

11

Click 

Install

.

This installs System Protocol Tester, and displays the next screen of the 
wizard.

12

Clear the 

View Readme.txt

 check box if you do not want to view the 

Readme.txt

 file.

13

Clear the 

Run USB network adapter Config Helper

 check box.

14

Click 

Next

.

The InstallShield Wizard Complete screen appears.

15

Click 

Finish

.

This completes the System Protocol Tester installation.

Installing OBSAI Protocol Tester with the USB Network Adapter

To install OBSAI Protocol Tester with the USB Network Adapter:

1

Repeat steps 1 to 12 from the previous section.

2

Select the 

Run USB network adapter Config Helper

 check box.

Summary of Contents for N5340A

Page 1: ...Agilent Technologies Agilent OBSAI Protocol Tester Installation Guide ...

Page 2: ...d If software is for use in the performance of a U S Government prime contract or sub contract Software is delivered and licensed as Commercial computer soft ware as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication o...

Page 3: ...quipment s metal frame Indicates hazardous voltages and potential for electrical shock Indicates that antistatic precautions should be taken Indicates hot surface Please do not touch Indicates laser radiation turned on CSA is the Canadian certification mark to demonstrate compliance with the Safety requirements CE compliance marking to the EU Safety and EMC Directives ISM GRP 1A classification acc...

Page 4: ...for the ac mains voltage requirements and ambient operating temperature range Before Applying Power Verify that all safety precautions are taken The power cable inlet of the instrument serves as a device to disconnect from the mains in case of hazard The instrument must be positioned so that the operator can easily access the power cable inlet When the instrument is rack mounted the rack must be p...

Page 5: ...Installation Guide 5 Environmental Information ...

Page 6: ...troduction Provides a list of equipments supplied and information on what hardware and software should already be there before you move ahead in this guide Setting Up the Hardware Provides information on how to assemble the OBSAI Protocol Tester hardware equipments Installing OBSAI Protocol Tester Explains how to install the OBSAI Protocol Tester software Getting Started Explains how to start and ...

Page 7: ...gies 1 Introduction Equipments Supplied 8 Installation Requirements 9 This chapter provides a list of equipments supplied as part of standard shipment to customer and information on what hardware and software should already be there before you move ahead in this guide ...

Page 8: ...1 Introduction Equipments Supplied Agilent OBSAI Protocol Tester includes N5341A Base Station Link Test Module N5340A Base Station Test Extension Module N2X Chassis 2 slot or 4 slot The following cables RP1 cable RP3 cable ...

Page 9: ...ents of the Controller and Client PCs Controller PC Requirements Windows XP with Service Pack 2 operating system is installed At least 1 GB RAM is installed At least 500 MB free disk space is available on the C drive One 100BaseT LAN interface is installed for connection to the N2X chassis Agilent recommends to install two 100BaseT LAN interfaces for concurrent access to the corporate network or o...

Page 10: ...10 Installation Guide 1 Introduction ...

Page 11: ...ware Adjusting I O Modules Inside the Chassis 12 Connecting a Chassis to the Controller PC 16 Once all the system requirements are in place you need to start setting up the hardware for OBSAI Protocol Tester This requires you to set up basic hardware such as I O modules chassis and controller PC ...

Page 12: ... to attach as well as remove them to and from chassis Attaching an I O module to the chassis To attach an I O module to the chassis 1 Insert the I O module inside the empty slot and push it to adjust it inside the empty slot Figure 1 Chassis with an Empty Slot 2 Tighten the screw locks of the I O module The I O module is now attached to the chassis ...

Page 13: ...dule from the chassis hold it by the front panel and metal case and place it on a hard and flat surface WARNING Do not directly touch any component on the I O module It may be hot CAUTION Components on the I O module are sensitive to the static electricity Therefore take necessary anti static precautions such as wear a grounded wrist strap to minimize the possibility of electrostatic damage Also y...

Page 14: ...dule Figure 3 N5341A module To set the N5341A module For RP3 01 connection First ensure that SFP is inserted into the RP3 01 optical port Then connect the one end of the optical fibre cable to the RP3 01 optical port and the other end to device under test DUT For RP3 connection Connect the electrical Tx port of DUT to the Rx ports of the N5341A module ...

Page 15: ... 30 72 MHz will be available on Sys Clk Out When you are using N5341A as an RF module connect the sync burst and system clock from DUT to the sync burst in and sys clk in of the RP1 cable and connect the RP1 cable to the RP1 port For Ethernet connection Connect the LAN cable to the ethernet port of the module to provide ethernet functionality on the RP3 01 port Ensure that the ethernet connection ...

Page 16: ...on you can Connect the chassis to the Controller PC through the private LAN Use the USB network adapter which comes with OBSAI Protocol Tester as a second LAN interface The advantage of this arrangement is that you can access the Controller PC from anywhere within the corporate LAN For example multiple Client PCs can access the Controller PC through the corporate LAN To connect the master chassis ...

Page 17: ...chnologies 3 Installing OBSAI Protocol Tester Configuring the Controller PC 18 Installing OBSAI Protocol Tester 20 Setting Up the DHCP Service 25 Once you have set up the hardware you can start installing the software components that come with the installation CD ...

Page 18: ...ly when the default FTP service is not installed on the Controller PC Do not install WARftp prior to installing OBSAI Protocol Tester Uninstall WARftp if it is already installed as it halts the installation of OBSAI Protocol Tester If you are not allowed to use WARftp you can use the FTP server that comes with the Windows operating system In Windows FTP is a part of Internet Information Services I...

Page 19: ...ansfer Protocol FTP Server check box in the Sub components of Internet Information Services IIS list box This automatically selects the Common Files and Internet Information Services Snap In check boxes 7 Click OK This saves the changes you made and closes the Internet Information Services IIS dialog box 8 Click Next to install IIS 9 Click Finish to complete the installation process To Enable FTP ...

Page 20: ...ve The installation page appears 2 Click Installation The Install System Protocol Tester Software page appears 3 Click the System Protocol Tester hyperlink The File Download Security Warning dialog box appears This dialog box prompts if you want to run or save the Setup exe file 4 Click Run If legacy components are installed on your computer then a message box appears and prompts you to remove the...

Page 21: ...lient GUI only Select if you want to install only the Client software on your PC b Controller Client Full Select if you want to install both the Controller and Client software on your PC 10 Click Next The Ready to Install the Program screen appears 11 Click Install This installs System Protocol Tester and displays the next screen of the wizard 12 Clear the View Readme txt check box if you do not w...

Page 22: ...talling the USB Network Adapter Once you have used the USB network adapter in the installation process you can remove it However doing this does not releases the IP address assigned to the USB network adapter Therefore any attempts to use that port displays an error which prompts that the IP address is already assigned to a device To avoid this situation uninstall the USB network adapter before ph...

Page 23: ...This displays an expandable list of options in the right panel of the Computer Management window 4 Expand the Network adapters icon A list of network adapters attached to your computer is displayed 5 Right click the option that represents the USB network adapter 6 Select Uninstall from the context menu The Confirm Device Removal message box appears Figure 5 ...

Page 24: ...lling OBSAI Protocol Tester Figure 5 Confirm Device Removal message box 7 Click OK This uninstalls the USB network adapter You can now remove the USB network adapter from the computer and assign its IP address to some other device ...

Page 25: ... to listen to the responses answers sent from the Controller PC Setting up the DHCP service for System Protocol Tester requires you to configure the LAN card and configure the DHCP service Configuring the LAN interface You need to configure the LAN card on the Controller PC to establish a private LAN connection between the Controller PC and the chassis To configure the LAN interface 1 Click Start ...

Page 26: ...ile To restart the DHCP service To update the DHCP registry file and the system registry To update the DHCP configuration file 1 Go to the c dhcpdnt directory 2 Open the dhcpd conf file in a text editor 3 Modify the subnet netmask and range dynamic bootp parameters as desired 4 Save the dhcpd conf file 5 Close the dhcpd conf file To restart the DHCP service 1 Click Start Settings Control Panel The...

Page 27: ...tor dialog box appears asking if you want to update the system registry using the dhcpd reg file 7 Click Yes The Registry Editor message box displays prompting that the system registry has been successfully updated 8 Click OK Updating the DHCP configuration file to use MAC address If you do not want to use DHCP then you can use MAC addresses of the serial I O modules to assign them their IP addres...

Page 28: ...I O module 6 Replace the MAC address of the module parameter with the MAC address of the serial I O module You can find the MAC address of the serial I O module on its label 7 Replace the ip address to be assigned to this module parameter with the IP address of the serial I O module The IP address of the serial I O module should be within the defined subnet 8 Save the dhcpd conf file 9 Restart the...

Page 29: ...Tester Installation Guide Agilent Technologies 4 Getting Started Starting an OBSAI Session 30 Using OBSAI API Example 32 This chapter provides information on how to power up the system and the start and join a new OBSAI session ...

Page 30: ...ted to the Controller PC You can power up the chassis using the power switch which is at the front of each chassis Powering up the chassis also boots the I O modules installed in it 4 View the matrix display of the I O module After booting the I O module displays its number along with a trail of pixel snake around the border of the display area To start a new session 1 Invoke the Tcl command promp...

Page 31: ...e parameters and returns sessionHandle parameter ObsaiExerciser is a sessionType parameter AGT_SESSION_ONLINE is a sessionMode parameter 5 Specify the following command to add a port to the session AgtInvoke AgtPortSelector AddPort 101 1 This command creates a new session and returns you the unique session id such as 1 In the above command AgtPortSelector is an interface that provides methods to r...

Page 32: ... To create a trigger on RP1 range and type 1 Set the trigger properties as shown below AgtInvoke AgtObsaiExerciser SetRP1TriggerProperties PORT LINK_MAP 1000 0 2000 0 AGT_OBSAI_RP1_TYPE_RP3_FDD AGT_OBSAI_RP1_TYPE_CDMA_2000 0 The above statement sets the range for RP1 between 1000 and 2000 and alo sets RP1 type to AGT_OBSAI_RP1_TYPE_RP3_FDD and AGT_OBSAI_RP1_TYPE_CDMA_2000 2 Specify which property ...

Page 33: ...Installation Guide 33 ...

Page 34: ...Agilent Technologies Copyright Agilent Technologies 2008 Printed in Germany July 2008 ...

Reviews: