Protocol and triggering: Memory support (standard feature on the MSOX)

DDR2, 3, and 4 protocol and triggering 

Because of the introduction of MSO models on the 90000 
X-Series, these oscilloscopes now support full protocol and 
triggering for DDR2, 3 and 4 technologies. The 90000 X-Series 
allows for full triggering on the following events: read, write, 
activate, precharge, and many more common memory com-
mands.

The triggering makes read and write separation easy to do; it 
also helps you quickly find real time eyes in today’s difficult-
to-debug memory environment.  

The DDR2, 3 and 4 protocol triggering is only available on the 
MSO and comes standard with an MSO purchase.  

LPDR 2 and 3 protocol and search

The 90000 X-Series also provides LPDDR2 and LPDDR3 
protocol standard on its MSO. A time-aligned listing window 
makes it easy to search for uncommon events.

Summary of Contents for Infiniium 90000 X

Page 1: ...Agilent Infiniium 90000 X Series Oscilloscopes Combining deep logic analysis with the industry s highest performance oscilloscope Featuring the world s fastest mixed signal oscilloscope Data Sheet...

Page 2: ...improving The industry experts have spoken and the 90000 X Series is one of the most award winning oscilloscopes in the history of the oscilloscope industry With Agilent s 90000 X Series oscilloscope...

Page 3: ...up to the tough challenges today s high speed signal data rates with the following InfiniiMax III high frequency probes with automatic AC calibration PrecisionProbe Fully integrated probe amplifier s...

Page 4: ...ive Ultra VNC GPIB and LAN provide remote measurements Optional Infiniium application remote program interface allows application compliance software automation LXI class C compliant MATLAB support Ca...

Page 5: ...to fine vernier control by pressing the horizontal and vertical sensitivity knobs Increase your productivity with a familiar Infiniium graphical user interface including your favorite drag and drop m...

Page 6: ...RF signals or analyzing transient physical phenomena you need the truest representation of your signals under test Agilent invested in leading edge technology to bring you the highest real time oscil...

Page 7: ...rise times to be more accurately depicted The oscilloscope noise floor directly impacts the y axis voltage placement of each signal data point The Infiniium 90000 X Series scopes combine superiority...

Page 8: ...specifically targeted at the DDR2 3 4 technologies simplifying the complicated task of debugging memory technologies The 20 GSa s on 8 channels means you can easily separate reads and writes on all DD...

Page 9: ...ristics via s parameter files The InfiniiMax III probing system and the 90000 X Series communicate via an I C bus This communication allows the 90000 X Series to download the customized s parameter fi...

Page 10: ..._16 GHz_6 dB 344 4 374 41 8 7 8 GT s_12 GHz_P7 96 83 103 09 6 5 8 GT s_12 GHz_P8 100 16 108 33 8 2 8 GT s_16 GHz_P7 96 92 106 01 9 4 8 GT s_16 GHz_P8 100 24 108 24 8 0 By characterizing and compensati...

Page 11: ...and clock recovery Serial data analysis SDA software provides flexible clock recovery including 1st and 2nd order PLL and constant algorithms With a stable clock you can look at real time eyes of tran...

Page 12: ...evels either logic ones or logic zeroes deviat ing from their ideal positions Some tools simply provide a view of an eye contour but provide no real measurement data other than nice graphics EZJIT Com...

Page 13: ...u to define your system as you understand it and even make it arbitrarily complex You do this by selecting topologies and defin ing circuit blocks Model reflections With the InfiniiSim waveform trans...

Page 14: ...iScan software allows you to use an oscilloscope to identify signal integrity issues that hardware triggering is unable to find in your electronic designs This innovative software scans through thou s...

Page 15: ...insight Share scope measurements more easily across your team You can share entire data records instead of being limited exclusively to static screen shots Create more useful documentation Use feature...

Page 16: ...er 004 N5400A EZJIT Complete Understand your full real time by decomposing the noise that is impacting your margins 070 N8823A Serial data analysis Recover clocks to 120 Gbs s and view real time eyes...

Page 17: ...hat it will pass in test labs and at plug fests worldwide Agilent experts on technology boards and industry standards committees help define compliance requirements As a result you can be sure that 90...

Page 18: ...e full testing of your entire device Maintain accuracy The framework fully supports Agilent s PrecisionProbe soft ware N2809A and InfiniiSim software N5465A This gives you the ability to characterize...

Page 19: ...to create a full suite of measurements Full measurement report No automation would be complete without a simple to view and easy to understand report UDA provides a full report of the pass fail crite...

Page 20: ...ations 033 N5413B DDR4 verification Save time with automated testing based on JEDEC DDR4 specifications 058 N6462A MIPI D Phy verification Execute D Phy electrical checklist tests for CSI and DSI arch...

Page 21: ...ng events read write activate precharge and many more common memory com mands The triggering makes read and write separation easy to do it also helps you quickly find real time eyes in today s difficu...

Page 22: ...on of your SATA SAS designs with the full capability protocol viewer for 3 G 6 G and 12 Gbit s 018 N5436A DigRF v4 Extend your scope capability with DigRF v4 triggering and decode 051 N8807A I2C SPI E...

Page 23: ...p to 4 GHz 600 MHz 1 GHz 2 5 GHz 4 GHz 2 5 GHz 4 GHz 6 to 16 GHz 6 GHz 8 GHz 12 GHz 13 GHz 13 GHz 16 GHz 20 to 63 GHz 20 GHz 25 GHz 28 GHz 33 GHz 20 GHz 25 GHz 33 GHz 50 GHz 63 GHz Max upgradable band...

Page 24: ...Signal Oscilloscope MSOX92004A 20 GHz Mixed Signal Oscilloscope DSAX91604A 16 GHz Signal Analyzer DSOX91604A 16 GHz Digital Signal Oscilloscope MSOX91604A 16 GHz Mixed Signal Oscilloscope DSAX91304A 1...

Page 25: ...InfiniiMax III probe amp N2800A ZIF probe head N5439A Browser hand held probe head N5445A 16 GHz solder in probe head N5441A 26 GHz solder in probe head N2836A 3 5 mm 2 92 mm SMA probe head N5444A 45...

Page 26: ...0 3 0 DSOX90000A 004 N5393C BroadR Reach compliance DSOX90000A 065 N6467A MOST compliance DSOX90000A 073 N6466A Description Product number Model number PrecisionProbe software DSOX90000 001 N2809A 00...

Page 27: ...100 Mpts ch memory N2810A 200 Upgrade 100 Mpts ch to 200 Mpts ch memory N2810A 500 Upgrade 200 Mpts ch to 500 Mpts ch memory N2810A 01G Upgrade 500 Mpts ch to 1 Gpts ch memory N2810A 02G Upgrade 1 Gpt...

Page 28: ...to 499 mV div 2 2 V 500 mV div 2 4 V Offset accuracy 3 5 V 2 of channel offset 1 of full scale 1 mV 3 5 V 2 of channel offset 1 of full scale Dynamic range 4 div from center screen DC voltage measurem...

Page 29: ...Jitter SampleClock SlewRate Noise 5 2 TimeScaleAccy Reading 2 TimeScaleAccy Reading sec rms sec rms Acquired Time Range Internal Timebase Reference External Timebase Reference 10 ms 100 fs rms 100 fs...

Page 30: ...um real time sample rate 10 GSa s at 16 channels 20 GSa s at 8 channels Maximum memory depth per channel Up to 1 Gpt Minimum width glitch detection 50 pS Sampling modes Real time Successive single sho...

Page 31: ...any one selected input will generate the trigger Triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity Triggers on g...

Page 32: ...rigger modes Zone qualify Generic serial Measurement limit Non monotonic edge Runt Software triggers on the user defined zones on screen Zones can be specified as either must intersect or must not int...

Page 33: ...te CDR de emphasis Jitter separation Spectral Method narrow and wide tailfit Measurements Random Jitter RJ Deterministic Jitter DJ Aperiodic Bounded Uncorrelated Jitter ABUJ peri odic jitter data depe...

Page 34: ...drop measurement toolbar Measure menu access to all measurements up to ten measurements can be displayed simultane ously Front panel button activates up to ten pre selected or up to ten user deined a...

Page 35: ...232 serial Parallel PS 2 USB 2 0 hi speed host USB 2 0 hi speed device Dual monitor video output Auxiliary output Trigger output Time base reference output General Characteristics Temperature Humidit...

Page 36: ...36 Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to 90 GHz Industry leading specs Powerful applications...

Page 37: ...lity Management System Agilent Channel Partners www agilent com find channelpartners Get the best of both worlds Agilent s measurement expertise and product breadth combined with channel partner conve...

Reviews: