![Agilent Technologies Agilent 86120B User Manual Download Page 127](http://html.mh-extra.com/html/agilent-technologies/agilent-86120b/agilent-86120b_user-manual_2867999127.webp)
4-45
Programming
Lists of Commands
:CALCulate3:DELTa:WPOWer[:STATe]
Turns the delta wavelength and power measurement mode on
and off.
I
:CALCulate3:DRIFt:DIFFerence[:STATe]
Sets the drift calculation to subtract the minimum values
measured from the maximum values measured.
I
:CALCulate3:DRIFt:MAXimum[:STATe]
Sets the drift calculation to return the maximum power
(frequency) values measured.
I
:CALCulate3:DRIFt:MINimum[:STATe]
Sets the drift calculation to return the minimum power
(frequency) values measured.
I
:CALCulate3:DRIFt:PRESet
Turns off all the drift states for DIFFerence, MAXimum,
MINimum, and REFerence.
I
:CALCulate3:DRIFt:REFerence:RESet
Places the current list of signals into the reference list.
I
:CALCulate3:DRIFt:REFerence[:STATe]
Turns the drift state on and off so that CALC3:DATA? will return
the reference signal list.
I
:CALCulate3:DRIFt[:STATe]
Turns the drift measurement calculation on and off.
I
:CALCulate3:POINts?
Queries the number of points in the data set.
I
CALCulate3:PRESet
Turns off any CALCulate3 calculation that is on.
I
:CALCulate3:SNR:AUTO
Selects the internal or externally entered frequency value for the
noise measurement reference in the SNR calculation.
I
:CALCulate3:SNR:REFerence:FREQuency
Sets the frequency used for the noise measurement reference in
the SNR calculation.
I
:CALCulate3:SNR:REFerence[:WAVelength]
Sets the wavelength used for the noise measurement reference
in the SNR calculation.
I
:CALCulate3:SNR:REFerence:WNUMber
Sets the wave number used for the noise measurement
reference in the SNR calculation.
I
:CALCulate3:SNR[:STATe]
Turns the SNR calculation on and off.
I
DISPlay Subsystem
:DISPlay:MARKer:MAXimum
Sets the marker to the signal with the largest power.
I
:DISPlay:MARKer:MAXimum:LEFT
Moves marker to signal with the next lower wavelength or
frequency.
I
:DISPlay:MARKer:MAXimum:NEXT
Moves the marker to the signal with the closest power level just
below the power level of the signal at the current marker
position.
I
:DISPlay:MARKer:MAXimum:PREVious
Moves the marker to the signal with the closest power level just
above the power level of the signal at the current marker
position.
I
:DISPlay:MARKer:MAXimum:RIGHt
Moves marker to the next higher wavelength or frequency.
I
:DISPlay[:WINDow]:GRAPhics:STATe
Turns the instrument display of the power bars on and off.
S
Table 4-7. Programming Commands (3 of 4)
Command
Description
Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.
Summary of Contents for Agilent 86120B
Page 1: ...Agilent 86120B Multi Wavelength Meter User s Guide ...
Page 11: ...Contents 3 Contents Power Cords 8 16 Agilent Technologies Service Offices 8 18 ...
Page 12: ......
Page 38: ......
Page 68: ......
Page 100: ...4 18 Programming Monitoring the Instrument ...
Page 132: ......
Page 230: ......
Page 248: ...8 6 Reference Menu Maps Delta On Menu Delta Off Menu ...
Page 250: ...8 8 Reference Menu Maps System Setup Menu ...
Page 268: ......