3. Installation
12
PNEG-2339
Flex-Flo Unloader Kit
Installing the Slide Gate
1. Insert the slide (14) into the transfer plate (12). Install the slide shield (15) to the transfer plate (12)
using two 5/16" x 1" truss head screws (4) and 5/16" hex nuts (11).
NOTE:
Make sure the slide (14) is in operating position. Pass the free end of the chain through the
slide shield (15) and secure it to the slide (14) with a cotter pin.
Figure 3E Installing the Slide and the Slide Shield
2. Install the unloader (23) to the transfer plate assembly (22) using 5/16" x 1" MS screws (5) and
Figure 3F Installing the Unloader Assembly
Ref #
Part #
Description
4
S-4336
5/16"-18 x 1" Truss Head
Machine Screw
11
S-396
Hex Nut 5/16"-18 YDP Grade 2
12
BLK-10496
Transfer Plate
14
FLX-4782
Slide Gate
15
BLK-10497
Slide Gate Shield
Ref #
Part #
Description
5
S-8328
Screw, MS 5/16"-18 x 1" RHS ZN
Grade 2
11
S-396
Hex Nut 5/16"-18 YDP Grade 2
22
Transfer Plate Assembly
23
Unloader Assembly