3. Installation
Installing the Boot and Transfer Plate
NOTE:
Installation of the boot is the same whether the tank has the standard collar or the Sure-Flo Feed
Flow Control.
1. Slide the boot (33) as far as possible into the tank collar (32) or the Sure-Flo Feed Flow Control
opening.
Figure 3A Inserting the Boot into the Collar
2. Align the boot (33) with the Flex-Flo system that will be installed.
3. Using the holes in the tank collar (32) as a guide, drill eight 11/32" holes (21) into the boot (33) rim.
Figure 3B Drilling Holes in the Boot
Improper installation methods of the hardware may cause permanent damage and
possible breakage of the boot.
CAUTION
Ref #
Description
32
Tank Collar
33
Boot
Ref #
Description
21
11/32" Field Drill Hole
32
Tank Collar
33
Boot