INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
36
Refitting the Range
Reverse the above procedure to refit. If the gas line has been
disconnected, check for gas leaks after reconnection.
Note:
A suitably qualified person should disconnect and
reconnect the gas supply.
The service engineer MUST follow the installation instructions
provided with the gas appliance connector and the warning
label attached to the connector.
If the range is removed for any reason, make sure that the
anti-tip device is re-engaged properly when the range
is replaced. Failure to take this precaution could result in
tipping of the range and may cause injury.
Customer Care
Please complete your details in this Guide, inform the user
how to operate the range and hand over the Instructions.
Thank you
Range Operational Checks
Oven Check
Turn on the oven and check that the oven fans start to turn
and that the oven starts to heat up. Turn off the oven.
Oven Light Check
Press the oven light switch and check that the lights are
working.
Note:
The oven light bulbs are not included in the warranty.
Ignition of the Cooktop Burners Check
Operation of all cooktop burners should be checked after the
range and gas supply lines have been carefully checked for
leaks.
Check each burner in turn. There is a flame safety device that
stops the flow of gas to the burner if the flame goes out.
There is also a spark ignition system that works when the
knob is pressed in.
For each burner, push in and turn a knob to the lighting
position.
The igniter should spark and light the gas. Keep holding the
knob pressed in to let the gas through to the burner for few
seconds.
If, when you let go of the control knob, the burner goes out,
the safety device has not held in. Turn the control to the
off position and wait one minute, then try again this time
holding in the control knob for slightly longer.
Quality of Flames
If the flame is distorted, check that the burner head is
correctly placed over the burner base.
n
n
MAKE SURE THE FLOW OF COMBUSTION AND
VENTILATION AIR TO THE RANGE IS UNOBSTRUCTED.
n
n
MAKE SURE ALL CONTROLS ARE LEFT IN THE OFF
POSITION.
Moving the Range for Servicing
Follow these procedures to remove appliance for servicing:
Shut off the gas supply and turn off the circuit breaker.
Disconnect gas supply tubing to the appliance and unplug
the electrical supply cord.
Note:
A suitably qualified person should disconnect and
reconnect the gas supply.
The range is very heavy, so take great care. We recommend
two people maneuver the range. Ensure that the floor
covering is firmly attached, or removed to prevent it being
disturbed when moving the range around. You will need the
leveling tool.
Before attempting to move the range, see
‘Moving the range’.
Summary of Contents for Professional 90 Dual Fuel