Installation 

 

Make sure the gate is level and swings freely.  The gate must not have a wheel. 
 
Determine if it will be a pull-to-open (swing in) or a push-to-open (swing out) setup.   

 

Typically, the gate will swing in toward the house, which is a pull-to-open setup.   
Sometimes the gate must swing out towards the street, for example when the driveway 
slopes up to the house, which is a push-to-open setup. A special post bracket is needed for a 
push-to-open setup. 
The gate operator arm mounts on the inside of the gate in either setup.   
 

Posts, Columns and Walls 

 
It is recommended to mount the post bracket on a steel post, which is at least 3” wide.   
If a wood post is used, it should be pressure treated, plumb and square, and at least 6” wide.  
It is recommended to re-tighten your bolts occasionally because wood tends to shrink and 
expand.   
 
The hinges cannot be mounted in the center of a column.  The angle will be too wide. 
If you mount on a column, make sure that the gate hinges are within 4” of the back of the 
column. 
 
If the hinges are in the center of a column, you could notch the column to accommodate the 
operator, or you could re-mount the gate hinges on a post behind the column.   
 
You could consider swinging the gate out, in which case you could put your operator post 
bracket on the same face as the hinges.   
 
Here is an example of a push-to-open setup where the bracket is mounted on the same pillar 
face as the gate hinges: 

 

Be sure to leave enough space when the gate is opening.  Here is a picture of a pull-to-open 
setup where the post bracket is mounted on the back of the column, next to a wall. Allow at 
least 6” between the gate and the wall or the operator will bind, and the gate won’t be able 
to open all the way.  Note that the maximum distance from the pivot point of the hinge to 
the back of the pillar is 6”. 

Summary of Contents for GATEMASTER 900 HD

Page 1: ...1 AGA GATEMASTER 900 HD AGA GATEMASTER 900 HD Installation Manual...

Page 2: ...d with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions Failure to follow installati...

Page 3: ...ny components unless shown in this manual Do not try to manually open or close the gate without pulling up the release lever If there is a failure that cannot be solved and is not mentioned in this ma...

Page 4: ...length 12 inches Power supply 110V AC converted to 24V DC with built in transformer Nominal input power 2A Maximum operating current 5 5A for maximum 10 seconds Maximum gate weight 500 lbs Maximum gat...

Page 5: ...to shrink and expand The hinges cannot be mounted in the center of a column The angle will be too wide If you mount on a column make sure that the gate hinges are within 4 of the back of the column If...

Page 6: ...6...

Page 7: ...gate open NOTE The operator shaft will be fully extended when the gate is closed and fully retracted when the gate is open Note that there is not a limit setting on the control board Simply manually...

Page 8: ...release lever then extend the arm all the way out The arm will be in this completely extended position when the gate is closed Determine where you will mount the operator It is better to be near the...

Page 9: ...ng points Making sure the bracket is level drill four 3 8 holes through the hinge post and fasten the bracket with nuts and washers Note Drilling and bolting all the way through the post is the strong...

Page 10: ...will be in this completely retracted position when the gate is closed The arm will be completely extended when the gate is open Determine where the operator will be mounted It is better to place it n...

Page 11: ...is the strongest method but if it is not possible to drill through the post you could use quarter inch self tapping screws If that is necessary regularly check that the screws are tight Drill and bol...

Page 12: ...amp hour batteries must be wired IN SERIES to provide 24V DC See wiring diagram Important Connect the charge controller to the batteries FIRST and then connect the solar panel to the charge controlle...

Page 13: ...up Battery backup is not required In the event of a power failure there is a manual release lever on the top of each operator arm which allows the gates to be opened manually Turn the key and lift the...

Page 14: ...onal accessory wires Connect the Operator Arms Cables to the Control Board Bi Parting Double Gate Connect cable from the Primary operator arm on the near side of the driveway Connect the Black wire to...

Page 15: ...E Have the keypad in hand at the gate control box when programming Do not mount keypad on gooseneck mounting post yet Step 1 Program the keypad to the gate operator Enter 0000 to enter programming mod...

Page 16: ...may be mounted on brackets mounted to the gate posts or on small metal or wood stakes on each side of the driveway For a double gate photo eyes are mounted to shoot the beam directly across the drive...

Page 17: ...s triggered to open Dig a shallow trench and bury the exit sensor It is not necessary to use a PVC conduit but it is a good idea in order to protect it and to make it easier to replace Wiring Instruct...

Page 18: ...its own radio receiver and two remotes come with the system In some cases you might want to add another receiver for example if you want to use a different wireless keypad such as the Liftmaster KPW5...

Page 19: ...19...

Page 20: ...output is used for connecting photo eye sensor Continuous output current 200mA 8 24V battery output is used for connecting the backup battery 9 24V battery output is used for connecting the backup bat...

Page 21: ...it means the system is normal Basic Function Setting Method To begin programming press and hold the FUN function button until the digital display shows P0 Press INC or DEC to increase or decrease the...

Page 22: ...t is 0 seconds P8 Sets the close delay time for the gate to close when utilizing a magnetic lock This staggers the gates so that they don t close at the same time Can be set from 0 to 10 seconds 1 mea...

Page 23: ...t this to 1 for a Single gate or 2 for Double gates NOTE Keypad should be set to channel 2 for a double gate Pd Safety photo beam setting Specifies which type of contact the safety photo beam is using...