background image

DirectCommand

 Installation 

Apache AS715/1010/1210 (MY 2009-2010)

 

Ag Leader Technology 

 

 

PN: 2005943 Rev. D 

December 2013 

Page 9 of 13

 

“AUXILIARY INPUT MODULE” into the Auxiliary Input Module 
receptacle labeled 

SWITCH B.

 

 

11.  Connect the brown plug labeled “APACHE” on the Switchbox 

Adapter Cable into the machine harness.  

 

12.  Use the Deutsch 6-Pin Dust Plug, PN: 2002899-6, to fill the 

empty receptacle labeled 

RADAR

 on the Auxiliary Input Module.  

 

NOTE: If a backup radar or wheel speed sensor has been 
installed on the machine, contact your Ag Leader Dealer 
for the appropriate cabling to connect the Radar to the 
Auxiliary Input Module 

 

13.  Locate the Power Studs in the cab shown in the figure above. 

Connect the fused wires from the Power Cable, PN: 4002016-5 
to the Positive Terminal, and the black wires to the Negative 
Terminal. 

 

14.  Route the opposite end of the Power Cable towards the Auxiliary 

Input Module. Connect the 3-pin Weatherpack Tower of the 
Power Cable to the mating connector on the Display Cable.  

 

 

Summary of Contents for DirectCommand

Page 1: ...Y Splice 4000137 1 CAN Bus Terminator 4000141 1 Liquid Product Control Module 4000394 1 CAN Bus Stub 8 in 4000450 1 1 Flow Control Cable 4000451 6 1 Implement Stub 4000495 1 1 Apache Switchbox Adapte...

Page 2: ...and operation of this product CAUTION will alert you to situations that will impact the physical safety of you or others IMPORTANT will alert you to the potential for damage to the product or loss of...

Page 3: ...n contains illustrations of components common to all DirectCommand installations Their purpose is to ensure proper identification and installation in the sections that follow CAN Bus connectors 1 Term...

Page 4: ...Ag Leader Technology DirectCommand Installation Apache AS715 1010 1210 MY 2009 2010 Page 4 of 13 December 2013 PN 2005943 Rev D Component and Cable Layout...

Page 5: ...panels for any hoses wiring controls etc that could be damaged when drilling any mounting holes IMPORTANT Disconnect the Display DirectCommand components and flow meter from electrical system when wel...

Page 6: ...Display NOTE The Raven boom section widths are in inches the Ag Leader Display requires boom widths in feet Divide the Raven widths by 12 before entering the widths into the Ag Leader Display 2 Run t...

Page 7: ...1 Deutsch Dust Plug 6 pin PN 2002899 6 1 CAN Y Splice PN 4000137 1 CAN Bus Stub 1 ft PN 4000219 1 1 Auxiliary input Module PN 4000437 From Display Kit or Display Cable Kit 4100814 1 Power Control Rel...

Page 8: ...Cable 6 Connect the Round 4 pin plug of the CAN Bus Stub 1 ft PN 4000219 1 into the gray side of the CAN Y Splice 7 Connect the opposite end of the CAN Bus Stub into the mating receptacle on the Auxil...

Page 9: ...ADAR on the Auxiliary Input Module NOTE If a backup radar or wheel speed sensor has been installed on the machine contact your Ag Leader Dealer for the appropriate cabling to connect the Radar to the...

Page 10: ...4001808 24 Step by Step for Installing the External Cabling and Liquid Control Module 1 Connect the 2 pin Deustch Receptacle on the Hi Current Power CAN Bus Extension Cable PN 4001808 24 to the matin...

Page 11: ...Implement Plug PN 4000495 1 into the receptacle labeled AUXILIARY on the Liquid Control Module 7 Connect the 2 pin plug on the Hi Current Power CAN Bus Extension Cable into the 2 pin receptacle comin...

Page 12: ...oom Cable into the appropriate Boom Valve NOTE Leave dust caps installed on all unused connectors in the 10 Section Boom Cable 15 Connect the gray 8 pin plug on the Flow Control Cable PN 4000451 6 int...

Page 13: ...Threshold setting Decreasing this value will cause the servo valve to run slower Allowable Error 2 Determines the percent error that is allowed prior to the product control system making any flow rate...

Reviews: