EN
5
www.afx-light.com
CONTROL PANEL
UP
DOWN
MENU
ENTER
8.8.8.8.
To access the main menu press the MENU button. Press the UP or DOWN
buttons until you reach function you wish to change. When you reach the
function you wish to change, press the ENTER button. When a function
is selected, use the UP or DOWN buttons to change the function settings.
Once your changes are made, press the ENTER button.
FUNCTION MENU
Address Set
DMX Address setting
Run mode
DMX
Auto 1 – Auto2
AUTO
SOUND
MANUAL
Manual Test -> Function and Operation
SETUP
Advanced setting
Pan reverse
Tilt reverse
Display
Screen Reverse
Channel (16/14/12/10 Select)
Sensitivity (01-100)
Motor zero
Reset
Factory Set
System
Infor
-
mation
Ver V1
DMX address
Temperature
PHOTOMETRIC DATA
CLEANING
Due to fog residue, smoke, and dust cleaning the internal and external lenses should be carried out
periodically to optimize light output.
•
Clean regularly the air vents and fans.
•
Use normal glass cleaner and a soft cloth to wipe down the out-side casing.
•
Clean the external optics with glass cleaner and a soft cloth every 20 days.
•
Always be sure to dry all parts completely before plugging the unit back in.