![AFRISO SonarFox UST 20 Operating Instructions Manual Download Page 33](http://html.mh-extra.com/html/afriso/sonarfox-ust-20/sonarfox-ust-20_operating-instructions-manual_2864831033.webp)
33
AFRISO
SonarFox UST 20
Area classification (according to EN 60079-10 and EN 60079-14)
UST 20_-01
Basic version for non-hazardous areas
UST 20-_01_EX
UST 20-_11_EX
Intrinsically safe version for use in hazardous areas (explosive gas
atmospheres or explosive atmospheres with vapours)
II 1/2G Ex ia IIB T5
with intrinsically safe supply units, whole sensor zone 1, Front part of the unit
zone 0
UST 20-_21_EX
Intrinsically safe version for use in hazardous areas (flammable vapors or
gases)
II 1/2G Ex ia IIA T5 with intrinsically safe supply units, whole sensor
zone 1, Front part of the unit zone 0
UST 20-_31_EX
Intrinsically safe version for use in hazardous areas (flammable vapors or
gases)
II 2G Ex ia IIA T5 whole sensor zone 1