6.3
Connection thread
Verify that the correct instrument connection was selected.
The pressure connections must be tight. You may only use a suitable seal
whose material is compatible with the fluid to seal the connection.
Cylindrical threads
1. Seal the sealing surface (1) with a
suitable flat gasket (as per EN
837-1) or with lens-shaped rings
for the corresponding high-pres-
sure connections.
Conical threads (for example, NPT,
pipe thread as per EN 10226)
2. Seal with sealing material such as
PTFE tape, hemp) when screwing
the threads (2) together.
3. Verify tightness of the threaded
connections during the first pres-
sure measurement.