24
Mounting
EN
RF ... EX / KP ... EX / PF ... EX
6.2
Mounting a pressure gauge with clamp chemical seal
1. Remove the protective cap of the chemical seal immediately before ins-
tallation.
2. Protect the diaphragm from damage during mounting.
3. Do not touch the diaphragm with pointed objects.
4. Mount the product only to a suitable clamp connection piece, with suitable
clamp and sealing ring (as per ISO 2852).
5. Fit a suitable protective plastic cap after dismounting.
A. Product with chemical seal
B. Clamp
C. Clamp connection piece
D. Diaphragm
E. Sealing ring
A
B
C
E
D