– English –
Maintenance
FloCo-Top-2
37
8
Maintenance
Table 5: Maintenance times
When
Activity
If required
Clean the plastic parts with soap suds,
do
not use
cleaning agents containing sol-
vents.
Annually or if
required
Replacing the filter insert
Every 5 years
Replacing the burner hoses
No later than
after 20 years
Replace product
8.1
Replacing the filter insert / draining the liquid
The filter cup can be drained prior to dismounting to allow for easy
replacement of the filter insert.
1.
Place a suitable container with a capacity of at least 0.5 l below
the filter cup.
2.
Plug a drain hose Ø 6 mm auf onto the bleed screw. Suspend
the other end of the drain hose into the container.
3.
Turn the bleed screw counter clockwise.
4.
Slightly open the union nut of the filter cup with an oil filter
spanner.
Fig. 34: Draining the liquid
The liquid is drained into the container.
The filter cup is completely empty.
5.
Screw off the filter cup and replace the filter insert.
6.
Manually fit the union nut and close the drain valve.